INSTALLATION
Flare nut must use a torque wrench without fail. Tighten with the specifi ed tightening torque.
MANUAL
If the fl are nut is tightened too much, after a long period of time, the fl are nut breaks, Gas
leakage, stagnation, touching fi re, rarely cause ignition.
Sharp bending of the pipe use the polyethylene rod, bend not crushed the pipe. Gas leakage
from the crushed part, stagnation, touching fi re, rarely cause ignition.
Please request your sales agent or qualifi ed technician to install your unit. Water leakage,
short circuit or fi re may occur if you do the installation work yourself.
Please observe the instructions stated in the installation manual during the process of
SPLIT UNIT AIR CONDITIONER
installation. Improper installation may cause water leakage, electric shock and fi re.
Make sure that the units are mounted at locations which are able to provide full support to
INDOOR UNIT
the weight of the units. If not, the units may collapse and impose danger.
RAS-PH30HLT
Please ensure smooth fl ow of water when installing the drain hose.
Piping shall be suitable supported with a maximum spacing of 1m between the
supports.
OUTDOOR UNIT
Please use the specifi ed components for installation work. Otherwise, the units may collapse
or water leakage, electric shock and fi re may occur.
RAC-PH30HLT
Be sure to use the specifi ed piping set for R32. Otherwise, this may result in broken copper
pipes or faults.
When installing or removing an air conditioner, only specifi ed refrigerant (R32) shall be
allowed, do not allow air or moisture to remain in the refrigeration cycle. Otherwise, pressure
in the refrigeration cycle may become abnormally high so that a rupture may be caused.
Be sure to ventilate fully if a refrigerant gas leak while at work. If the refrigerant gas comes
into contact with fi re, a poisonous gas may occur. Be aware that refrigerants may not contain
EN INSTRUCTION MANUAL
an odour.
After completion of installation work, check to make sure that there is no refrigeration gas
FOR SERVICE
leakage. If the refrigerant gas leaks into the room, coming into contact with fi re in the fan-
driven heater, space heater, etc., a poisonous gas may occur.
PERSONNEL ONLY
Unauthorized modifi cations to the air conditioner may be dangerous. If a breakdown occurs
please call a qualifi ed air conditioner technician or electrician. Improper repairs may result
in water leakage, electric shock and fi re, etc.
Must install air conditioner according to the electrical installation standards for Thailand of
the Engineering Institue of Thailand under The Royal Patronage of His Majesty (the King).
Carefully read through the procedures of
proper installation before starting installation
work.
The sales agent should inform customers
A circuit breaker must be installed. Without a circuit breaker or fuse the danger of electric
regarding the correct operation of installation.
shock exists.
The external switch shall be incorporated to completely disconnect from power supply. It
Tools Needed For Installation Work
should disconnect all poles, and a contact separation of at least 3mm must be present.
(
mark is tool exclusive use for R32)
Do not install the unit near a location where there is fl ammable gas. The outdoor unit may
+
– Screwdriver
Measuring Tape
catch fi re if
Knife
Saw
Pipe Cutter
fl ammable gas leaks around it.
Hexagonal Wrench Key (
4mm)
Do not install the indoor unit in a machine shop or kitchen where vapor from oil or its mist
Power Drill (ø 65mm ~ ø 80mm)
fl ows to the indoor unit. The oil will deposit on the heat exchanger, thereby reducing the
Vacuum Pump
Pliers or Wrench
indoor unit performance and may deform and in the worst case, break the plastic parts of
Torque Wrench
Vacuum Pump Adaptor
the indoor unit.
Flare Tool
Gas Leakage Detector
Please ensure smooth fl ow of water when installing the drain hose.
Piping shall be suitable supported with a maximum spacing of 1m between the supports.
Manifold Valve
Charge Hose
SAFETY PRECAUTION
Read the safety precautions carefully before operating the unit.
The contents of this section are vital to ensure safety. Please pay special attention to the following sign.
!
WARNING ........ Incorrect methods of installation may cause death or serious injury.
CAUTION ......... Improper installation may result in serious consequence.
!
Be sure that the unit operates in proper condition after installation. Explain to customer the proper way of operating
the unit as described in the user's guide.
<IA1890: B >
Installation of Hanger, Wall Penetration and Installation of Protection Pipe
1
CAUTION
!
The draining of the water container inside the indoor unit can be done from the left.
Therefore the mounting plate must be fi xed horizontally or slightly tilted towards the
side of drain hose. Otherwise, condensed water may overfl ow the water container.
Direct Mounting On The Wall
Please use hidden beams in the wall to hold the mounting plate.
Mark
Screw for Mounting Plate
Please use more than
4 screws.
Line
Procedures of Installation and Precautions
Procedures to fi x the mounting plate.
1. Drill holes on wall.
2. Push plug into the holes.
(As shown below)
(As shown below)
Wall
Mounting plate
Plug
Screw
Wall
4.1 x 32 Screw
Procedures to fi x the holder of remote control.
1. Drill holes on wall.
2. Push plug into the holes.
(As shown below)
(As shown below)
Wall
Remote
Control
Holder
Screw
Plug
Wall Penetration and Installation of Protection Pipe
Drill a ø 65mm hole on
Indoor
Outdoor
wall which is slightly tilted
towards the outdoor side.
Drill the wall at a small
Seal with
Seal with
putty
angle.
putty
Cut the protection pipe
according to the wall
thickness.
Empty gap in the sleeve
of protection pipe should
WALL
be completely sealed with
putty to avoid dripping of
Protection
rain water into the room.
pipe
Sleeve of
protection pipe
<
>
IA1890: B
WARNING
!
CAUTION
!
2
Installation of the Indoor Unit
VERTICALLY DOWNWARD PIPING
Preparation
Connect connecting cord.
Pull out the pipe, connecting cord and drain hose.
Installation
The upper part of the indoor unit is hanged on the mounting plate.
The projection at the lower part of the indoor unit is hooked onto the mounting plate.
Mounting plate
Refrigerating
Pipe
Protection
Pipe
Drain Hose
Level
Push up the (PUSH) sections at the bottom of the indoor unit and
pull the bottom plate towards you. Then the claws are released from
Mounting
the stationary plate.
plate
(The (PUSH) sections are indicated by 2 arrows in the right fi gure)
HORIZONTAL PIPING
Hole for pipe
Weight
Preparation
Change of Drain Hose and Installation Procedures.
Exchange the location of drain hose and drain cap during horizontal piping as shown in
fi gure below. Be sure to plug in the drain hose until the insulating material folds upon itself.
3. Fix the mounting plate on wall
with 4.1 x 32 screw
Please use pliers to pull
(As shown in fi gure below)
out the drain cap.
Ceiling
(This is an easier way to
remove the drain cap).
Drain cap
Drain cap
Remove the cap for
drain hose installation
WARNING
!
2 ~ 5mm
Be sure that the wire is not
in contact with any metal
in the wall. Please use
the protection pipe as wire
passing through the hollow
part of the wall so as to
prevent the possibility of
damaged by mouse.
Unless it seals completely,
!
any air with high humidity
flows from outdoor and
Condensed water may leak out if not
dew may drop.
inserted properly.
THE CHOICE OF MOUNTING SITE
WARNING
!
The unit should be mounted at stable, non-vibratory location
which can provide full support to the unit.
CAUTION
!
No nearby heat source and no obstruction near the air outlet is allowed.
The clearance distances from top, right and left are specifi ed in fi gure
below.
The location must be convenient for water drainage and pipe connection
with the outdoor unit.
To avoid interference from noise please place the unit and its remote
controller at least 1m from the radio, television and inverter type
fl uorescent lamp.
To avoid any error in signal transmission from the remote controller,
please put the controller far away from high-frequency machines and
high-power wireless systems.
The installation height of indoor unit must be 2.3m or more.
Names of Indoor Components
No.
Component's Name
Qty
Mounting Plate
1
1
Screw for Mounting Plate
6
2
( 4 . 1 x 3 2 )
Holder for Remote
Controller
1
3
AAA Size Battery
2
4
Screw for holder of
Remote Controller
2
5
( 3 . 1 x 1 6 )
Remote Controller
6
1
Purifying Filter
2
7
WARNING
This symbol shows that this equipment
uses a fl ammable refrigerant.
If the refrigerant is leaked, together
with an external ignition source, there
is a possibility of ignition.
CAUTION
This symbol shows that the Operation
Instructions should be read carefully.
CAUTION
This symbol shows that a service
personnel should be handling this
equipment with reference to the
Installation Manual.
CAUTION
This symbol shows that there is
information included in the Operation
Manual and/or Installation Manual
Connecting cords,
pipe and drain
hose must be laid
together with Vinyl
tape.
Mounting plate
CAUTION
!
Lift the body
of the unit
Please pull the lower part of
upwards and
the indoor unit outwards to
then force it
check if the unit is hooked
downwards.
onto the mounting plate.
Improper installation may
Projection
cause vibration and noise.
Connecting Cord
HOW TO REMOVE INDOOR UNIT
[Push] mark positions
CAUTION
For horizontally out to right piping
GOOD
For right piping, follow the instruction as below:
Press the upper side of clamp
Unfold the pipe to downward slowly.
Drain hose
Drain hose
Bend the pipe to the right side of chassis.
Drain cap shall
be fully tightened
BAD
by pushing with
Following bending from left to right directly
Hexagonal wrench
could cause damage to pipe.
key when changing
location.
Drain hose
Please insert until here
CAUTION
(Please note the following matters and obtain permission from customer before installation).
The outdoor unit must be mounted at a location which can support
heavy weight. Otherwise, noise and vibration will increase.
Selecting the installation location: Suitable location that will reduce the
impact from rain and direct sun that may affect the unit performance.
Besides that, ventillation must be good and clear of obstruction.
The air blown out of the unit should not point directly to animals or plants.
The clearances of the unit from top, left, right, front and back are specifi ed
in fi gure below. At least 3 of the above sides must be open air.
Be sure that the hot air blown out of the unit and noise do not disturb
the neighbourhood.
Do not install at a location where there is fl ammable gas, steam, oil and
smoke.
The location must be convenient for water drainage.
Place the outdoor unit and its connection wire at least 1m away from the
antenna or signal line of television, radio or telephone. This is to avoid
noise interference.
Direction of Piping
Do not install outdoor unit facing strong wind direction. It may damage
the fan motor.
Horizontally
Do not install the outdoor unit in a place where small animals may build
perpendicular
their nests. If small animal goes inside the unit and touches the electrical
to the unit
parts, failure of the unit, smoke or fi re may be caused. Request your
customer to keep the surrounding of the unit is clean.
Connection
There are 6 directions allowed,
Figure showing the Installation of Indoor and Outdoor Unit.
namely, horizontally perpendicular
to the unit, vertically down from
right, horizontally out from right,
CAUTION
horizontally out to left,
!
horizontally out to right, vertically
This unit is chargeless up to 30m pipe length.
down from left.
Don't form the piping downward at
Installation of pipe length less than minimum pipe length
the left of the unit.
requirement (3 meters) may generate an abnormal sound.
Factory
Indoor
Dimension of Mounting Stand
Model
charge R32
A
of the outdoor unit
min
(unit : mm)
1.60kg
2.44m
RAC-PH30HLT
mounting stand
Be sure to
completely
above 100mm
seal any
gap with
putty.
above 100mm
CAUTION
A brazed, welded or mechanical
connection shall be made before
opening the valves to permit
refrigerant to fl ow between the
refrigerating system parts. A vacuum
valve shall be provided to evacuate
the interconnecting pipe and/or any
uncharged refrigerating system.
Mechanical connectors used indoor
shall comply with ISO 14903.
When mechanical connectors are
Plug
reused indoors, sealing parts shall
be renewed. When fl are joints are
reused indoors, the fl are part shall
be re-frabricated.
Refrigerant tubing shall be protected
or enclosed to avoid damage.
above 100mm
above 200mm
give clearance
as wide as
possible
above 100mm
above 700mm
above 200mm
INSTALLATION OF REFRIGERATING PIPES AFTER CONNECTION
The refrigerating pipes should be adjusted to fi t into the
hole on the wall and then ready for further connection.
The terminals of 2 connected pipes must be covered with
insulator used for terminal connection. Then the pipes
are wrapped with insulation pipe.
Connect the connecting cord after removing electrical
cover. (Refer to "CONNECTION OF POWER CORD")
After adjustment, fi t the connecting cord and pipes into
the space available under the indoor unit.
When connection is at left side, refrigerating pipe and
cabinet shall be tied together.
Failing to do so may cause the unit bottom side become
warping.
Excess binder shall be cut to prevent abnormal sound
and water dripping.
Binder
Insulation pipe (must be wrapped with vinyl tape at every 120mm).
THE CONNECTION OF REFRIGERATING PIPE DURING THE
INSTALLATION OF INDOOR UNIT
Preparation To Install Refrigerating Pipes
The refrigerating pipes and connecting cord
arrangement are attached.
The end of the refrigerating pipes are at locations
marked with "
" symbol.
Please bend at a small
radius to form an arc
Installation
Hang the Indoor unit onto the mounting plate. Use the temporary
stand at the back of the Indoor unit to push its lower part
15cm forwards.
Place the drain hose through the hole on the wall.
Wrap the refrigerating pipes with insulation pipe after
connecting refrigerating pipe.
Connect the connecting cord after removing electrical cover.
(Refer to "Connection of Power Cord")
After adjustment, the connecting cord and refrigerating pipes
are placed into the space available under the Indoor unit.
The projection of Indoor unit must hook to the mounting plate.
Heat insulation pipe
Pull this to the front
during the connection
Connecting
of refrigerating pipes
cord
to ease task.
Refrigerating pipe
3
Installation of Drain Hose
Condensed
Ditch
water pond
Bending upwards
Condensed water pond
You are free to choose the side (left or right) for the installation of drain
!
hose. Please ensure the smooth fl ow of condensed water of the Indoor
CAUTION
unit during installation. (Carelessness may result in water leakage.)
WARNING
!
CAUTION
!
Chargeless
Additional
Maximum
(m
2
)
up to
charge R32
R32
2
30m
––
1.60kg
above 100mm
2,300mm or more
The indoor piping
should be insulated
with the enclosed
insulation pipe. (If the
insulator is insuffi cient,
please use commercial
products).
The difference in height
between the indoor and
outdoor unit should be
kept max 20m.
The connecting pipe,
no matter big or small,
should all be insulated
with insulation pipe and
then wrapped with plastic
tape. (The insulator will
deteriorate if it is not
wrapped with tape).
The connection of insulated
drain hose.
inner diameter ø 16mm
Please use insulated drain
hose for the indoor piping
(commercial product).
Drain
hose
Connecting
Pipe
cord
CAUTION
!
The rubber strap used for
fi xing the insulator should
not be tied with great force.
Otherwise, this will damage
heat insulation and causes
water condensation.
Pipe
Rubber strap tied
with great force
CAUTION
!
Please fi x in the plastic core
after fl aring to avoid copper
chips entering the pipes.
below
5mm
Projection
Hook
about 15cm
Protection pipe
Drain hose
Connecting cord
Connected section
CAUTION
!
Be sure that the
drain hose is not
loosely connected
or bend.