CytroPac | Assembly
Display
STO event
StO-A
STO alarm
StO-r
STO request
StO-E
STO error
Bosch Rexroth AG, Edition 07.2022, RE 51055-B
Port 22X1 is designed as follows on the component side:
Table 6: Pin assignment of the device connector: Port 22X1
M12x1; 8-pole, A-coded
(device connector)
Pin 1, 6, 7, 8 must be isolated, since they are connected internally.
▶ In any case, use two input channels because using only one input channel
would reduce the safety integrity level.
Table 7: STO function: Diagnosis and state display
Description
STO function is activated correctly in stop mode; once the input
channels have been re-energized, the device goes to normal
state.
STO function is activated correctly in operating mode;
once the input channels have been re-energized, the device goes
to normal state.
STO function is activated incorrectly, this happens if one channel
is energized but the other is de-energized.
Hardware damage of the channel may also cause "StO-E" error.
The parameter [H0.03] is used to monitor the status of the STO function.
For further information on the parameters used, see the commissioning
instructions 51055-IB, see chapter 1.2 "Required and amending
documentation".
Pin
Function
1
Not used (NC)
2
STO 1 +
3
STO 1 -
4
STO 2 +
5
STO 2 -
6
Not used (NC)
7
Not used (NC)
8
Not used (NC)
Input channel logic
Channel
Channel
1
2
0
0
0
0
1
0
0
1