CytroPac | Assembly
Pin 5
Pin 6
Pin 7 and Pin 8
Ports 21X1 and 21X2:
Multi-Ethernet interfaces
Bosch Rexroth AG, Edition 07.2022, RE 51055-B
The digital input (input X2) of pin 5 is used to acknowledge errors (24 V: Reset).
In the premium version, this can be done either via the control word or via the
digital input. Nothing has to be changed for this. Alternatively, the error
acknowledgment (for commissioning) can be performed via the IndraWorks Ds
remote control.
The message warning (24 V) respectively no warning (0 V) is issued via pin 6.
This output is a relay output (extended relay output selection) and can also be set
via parameter [H8.21 or F2.41] to output other messages.
For further information on the allocation of inputs and outputs with functions,
see the chapter "CytroPac functions" of the commissioning instructions
51055-IB, see chapter 1.2 "Required and amending documentation".
Functions can be executed via the digital inputs of pin 7 (parameter input 1 - input
X4) and pin 8 (parameter input 2 - input X5). These inputs can be set via parameters
[F2.19/F2.20] for hydraulic functions or [E1.03/E1.04] for converter functions.
For further information on the allocation of inputs and outputs with functions,
see the chapter "CytroPac functions" of the commissioning instructions
51055-IB, see chapter 1.2 "Required and amending documentation".
Non-compliance with IP protection class when using standard RJ45 connectors!
Pushing the socket insert or jamming the connector!
Damage to the device socket and the hydraulic power unit!
▶ Use only suitable connectors for self-assembly or pre-assembled cables with
push-pull connector IP67 to standard RJ45 to ensure the IP protection class
and to prevent damage to the device socket.
The 21X1 and 21X2 multi-Ethernet interfaces are two RJ45 network ports.
With the aid of these interfaces, the hydraulic power unit can be operated via
a control communication via a higher-level control, connected to the IoT gateway,
established a connection to the PC (similar to the connection via mini-USB) and
a firmware update of the integrated network card can be installed.
The interface 21X1 (network input) is always connected. The interface 21X2
(network output) is used to connect further devices. When not in use,
close the connection to maintain the degree of protection.
NOTICE