Technical specifications
Article number
Interfaces
Number of PROFINET interfaces
1. Interface
Interface types
•
RJ 45 (Ethernet)
•
Number of ports
•
integrated switch
Protocols
•
IP protocol
•
PROFINET IO Controller
•
PROFINET IO Device
•
SIMATIC communication
•
Open IE communication
•
Web server
•
Media redundancy
PROFINET IO Controller
Services
PG/OP communication
–
Isochronous mode
–
Direct data exchange
–
IRT
–
PROFIenergy
–
Prioritized startup
–
Number of connectable IO Devices,
–
max.
Of which IO devices with IRT, max.
–
Number of connectable IO Devices for
–
RT, max.
of which in line, max.
–
Number of IO Devices that can be simul-
–
taneously activated/deactivated, max.
Number of IO Devices per tool, max.
–
Updating times
–
42
6ES7511-1AK02-0AB0
1
Yes; X1
2
Yes
Yes; IPv4
Yes
Yes
Yes
Yes; Optionally also encrypted
Yes
Yes
Yes
Yes
Yes; Requirement: IRT and isochronous mode
(MRPD optional)
Yes
Yes; per user program
Yes; Max. 32 PROFINET devices
128; In total, up to 256 distributed I/O devices can
be connected via AS-i, PROFIBUS or PROFINET
64
128
128
8; in total across all interfaces
8
The minimum value of the update time also de-
pends on communication share set for PROFINET
IO, on the number of IO devices, and on the
quantity of configured user data
CPU 1511-1 PN (6ES7511-1AK02-0AB0)
Equipment Manual, 05/2021, A5E40869673-AB