Fault Finding - Panasonic PAW-TD20C1E5-UK Installation Manual

Table of Contents

Advertisement

8. Fault Finding Guide
FAULT
No water flow from hot taps. 1. Mains supply off.
Water from hot taps is cold.
Intermittent water discharge. 1. Reduced expansion vessel charge.
Continous water discharge.
Important - note: Disconnect electrical supply before removing any electrical equipment covers.
Alternative Discharge
Discharge pipes should be in metal and
dedicated to the unvented cylinder. The pipe
should have a continuous fall and should terminate
in a safe and visible place.
Downward discharges at low level, i.e. up to 100 mm above
external surfaces such as car parks, hard standings, grassed
areas etc. are acceptable providing that where children may
play or otherwise come into contact with discharges,
a wire cage or similar guard is positioned to prevent
contact, whilst maintaining visibility.
Discharge at high level, i.e. into a metal hopper and metal
down pipe with the end of the discharge pipe clearly visible (tundish visible or not)
or onto a roof capable of withstanding high temperature discharges of water and
3 m from any plastics guttering system that would collect such discharges
(tundish visible).
Where a single pipe serves a number of discharges, such as in blocks of flats, the number served should be limited to
not more than 6 systems so that any installation discharging can be traced reasonably easily. The single common dis-
charge pipe should be at least one pipe size larger than the largest individual discharge pipe to be connected. For further
information contact your Building Control Office.
Table D
Minimum size of
Valve outlet size discharge pipe D1* from tundish
G1/2
G3/4
G1
10
POSSIBLE CAUSE
2. Strainer blocked.
1. Immersion heaters not switched on.
2. Immersion heater thermal cut-out has operated
3. Programmer set to central heating or not switched on.
4. Heat Pump/Boiler not working.
5. Cylinder thermal cut-out has operated (indirect units only).
6. Motorised valve not operating correctly.
1. Thermal control failure (Note: Water will be hot).
2. Cold water inlet Pressure Reducing Valve not working.
3. Temperature and pressure relief valve faulty.
4. Expansion relief valve not working properly.
Minimum size of
discharge pipe D2*
22 mm
15 mm
28 mm
35 mm
28 mm
22 mm
35 mm
42 mm
35 mm
28 mm
42 mm
54 mm
SOLUTION
1. Check and open stopcock.
2. Turn off water supply. Remove strainer and clean (see
Servicing Procedure page 10).
1. Check and switch on.
2. Check and reset button (see thermostat diagram page 8
and safety cut-out on page 5 of installation manual).
3. Check and set to hot water.
4. Check Heat Pump/Boiler operation. If fault suspected consult
installer or Heat Pump/Boiler manufacturer.
5. As at No. 2.
6. Check wiring and/or plumbing connections to motorised
valve (see pages 6 - 9 of the installation manual).
1. Follow instruction page 9: "Intermittent or slow water
discharge from tundish".
1. Switch off power to immersion heater(s) and heat pump/boiler
supply to the unit. When discharge has stopped, check thermal
controls, replace if faulty. Contact a competent person.
2. Check pressure from valve, if greater than 3 bar replace
(see page 9 of installation manual).
3. Drain 10 litres from cylinder and replace valve.
4. Check and replace if faulty (see page 6 of installation manual).
Maximum resistance allowed,
expressed as a lenght of straight
pipe (i.e. no elbows or bends)
up to 9 m
up to 18 m
up to 27 m
up to 9 m
up to 18 m
up to 27 m
up to 9 m
up to 18 m
up to 27 m
Resistance created by
each elbow or bend
0.8 m
1.0 m
1.4 m
1.0 m
1.4 m
1.7 m
1.4 m
1.7 m
2.3 m

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Paw-td30c1e5-ukPaw-td30c1e5hi-uk

Table of Contents