Maintenance Operation On The Refrigerating Circuit; Dismantling Of The Dryer - Beko DRYPOINT RA 200/AC NA Operating Manual

Refrigerating air dryer
Table of Contents

Advertisement

6.4.

Maintenance operation on the refrigerating circuit

CAUTION!
Refrigerant fluid!
Maintenance and service on refrigerating
engineers only, according to local rules.
All the refrigerant of the system must be recovered for its recycling, reclamation or destruction.
Do not dispose the refrigerant fluid in the environment.
This dryer comes ready to operate and filled with R134a or R404A type refrigerant fluid
In case of refrigerant leak contact a certified refrigerating engineers. Room is to be aired before any
intervention.
If is required to re-fill the refrigerating circuit, contact a certified refrigerating engineers.
Refer to the dryer nameplate for refrigerant type and quantity
Characteristics of refrigerants used
Refrigerant
R134a - HFC
R404A - HFC
6.5.

Dismantling of the Dryer

If the dryer is to be dismantled, it has to be split into homogeneous groups of materials.
Part
Refrigerant fluid
Canopy and Supports
Refrigerating compressor
Alu-Dry Module
Condenser Unit
Pipe
Fan
Valve
Electronic Level Drain
Insulation Material
Electric cable
Electric Parts
We recommend to comply with the safety rules in force for the disposal of each type of material.
The chilling fluid contains droplets of lubrication oil released by the refrigerating compressor.
Do not dispose this fluid in the environment. Is has to be discharged from the dryer with a suitable device
and then delivered to a collection centre where it will be processed to make it reusable.
DRYPOINT RA 200 – 2500 NA
Maintenance, troubleshooting, spares and dismantling
systems must be carried out only by certified refrigerating
:
Chemical formula
CH2FCF3
CH2FCF3/C2HF5/C2H3F3
Material
R404A, R134a, Oil
Carbon steel, Epoxy paint
Steel, Copper, Aluminium, Oil
Aluminium
Aluminium, Copper, Carbon steel
Copper
Aluminium, Copper, Steel
Brass, Steel
PVC, Aluminium, Steel
Synthetic gum without CFC, Polystyrene, Polyurethane
Copper, PVC
PVC, Copper, Brass
.
.
TLV
1000 ppm
1000 ppm
GWP
1300
3784
29