be connected to the expansion bus to save data
externally, in example to exchange defective devices
easily.
A D V I C E
Danger of damaging the device
Do not connect any USB devices!
Alarm relay (X2)
The EDS500 devices are equipped with a potential free
alarm output (relay with isolated switchover contact).
This output corresponds to a device alarm and is
activated when the device looses the power supply
or the alarm LED is constantly on. The reason for the
signaling of an alarm can be referenced in the system
alarm table (EDS500 Manual - Part 2: Alarms and alarm
configuration).
Pin allocation alarm output (X2)
Pin
Signal
1
2
3
4
1 & 2 Normal state
1 & 3 Alarm state
4
Common contact (connected to 1)
W A R N I N G
The relay is designed for switching only safety extra
low voltages.
Signaling
LED
Description Function
Power
Voltage
Supply
Ready
Ready
DSL1: Master DSL Master
mode
DSL1: Link
DSL link
established green
DSL1:
DSL Activity
Activity
Fo1: Module SFP Module
plugged
Fo1: Link
SFP link
active
Fo1: Activity SFP activity off
off
Device is without
power supply
green
Power supply
switched on
off
Hardware fault or
booting
green
Device ready
off
DSL unit in slave
mode
green
DSL unit in master
mode
off
No active DSL link
DSL link estab-
lished
off
No activity on the
DSL interface
green
Data is trans-
mitted via DSL
off
SFP not plugged
green
SFP plugged
off
no optical link
active
green
Optical link estab-
lished
No activity on the
optical interface
LED
Description Function
Con0: DCD
Con DCD
active
Con1: DCD
Con0:
Con activity
Activity
Con1:
Activity
Alarm
Alarm
Fo Alarm
SFP Alarm
Port 1-4: L
Ethernet
connection
Port 1-4: S
Ethernet
data rate
Port 1-4: PoE
Power over
En
Ethernet
enabled
Port 1-4: PoE
Power over
Act
Ethernet
active
Overall
Power
Allocation
During start-up all displays light up shortly for about
1 second. As soon as the start-up has been finalized
successfully (about 30 seconds after switching on the
device) the LED "Ready" switches to green.
Device configuration
The 500NMD43 can be configured locally as well as
from remote. In the following some methods are
introduced, for a complete description please see
EDS500 Manual - Part 2: Functions (1KGT151021).
Configuration using a serial configuration cable
In delivery status all serial interfaces are in
configuration mode to provide access to the command
line. Using a serial configuration cable (500CAB06
1KGT038912R0001), the device can be connected to a
serial port of a PC/notebook.
green
Data is trans-
mitted via the
optical interface
off
DCD inactive on
Con interface
green
DCD active
off
No activity on the
Con interface
green
Data is trans-
mitted via Con
off
No alarm
flash
Warning or
configuration
error
red
Alarm
off
No alarm
red
Alarm about the
SFP interface(s)
off
No connection
green
Link established
flash
Activity (send or
receive)
off
Data rate 10 Mbps
orange Data rate 100
Mbps
off
port not
configured for
PoE
green
port configured
for PoE
off
no PoE device
connected
green
PoE device active
supplied
0% to
Total sum of
100%
power requested
by connected PoE
devices