Connection Points - Bosch rexroth IndraDrive Instruction Manual

Drive controllers power sections hcs02
Hide thumbs Also See for rexroth IndraDrive:
Table of Contents

Advertisement

IndraDrive Drive Controllers Power Sections HCS02
4.2.2

Connection points

Symbols used to describe the connection points
Screw terminal block
Connection point
X3, X5,
X6
X9
X13
L+, L-
Apart from the indicated connections, it is necessary to wire the
Bb contact at the control section for signaling the readiness for
operation of the drive controller (see Project Planning Manual
"Rexroth IndraDrive Drive Controllers Control Sections").
For proper function of the motor thermal management connect the motor
thermal sensor as described in the wiring diagram. Otherwise motor
overtemperature sensing is not provided by the drive.
For Rexroth motors with data memory in the motor encoder, such as MSK,
the motor overload protection level is set automatically while connecting the
motor to the drive. There is no adjustment necessary. Otherwise refer to the
Rexroth firmware documentation.
Spring terminal
Tab. 4-1:
Symbols
HCS02
A, B
1) 2)
C
3)
A, B, C
B, C
A, B, C
B, C
1)
A: HCS02.1E-W0012
2)
B: HCS02.1E-W0028
3)
C: HCS02.1E-W0054, -W0070
Tab. 4-2:
Connection points
Thread
Max. connection cross
section
mm
(AWG)
2
4,0 (10)
16,0 (6)
1,5 (16)
4,0 (10)
1,5 (16)
M6
R911319657_Edition 09 Bosch Rexroth AG
15/21
Instructions for use
Max. tightening torque
Nm
0,6
1,7
-
1,7
-
6,5