Haier GE APPLIANCES NF96US Service Manual page 29

96 upflow/horizontal single stage constant torque motor gas furnace
Hide thumbs Also See for GE APPLIANCES NF96US:
Table of Contents

Advertisement

TYPICAL EXHAUST PIPE CONNECTIONS IN HORIZONTAL DIRECT OR NON-DIRECT VENT
DO NOT transition
from smaller to larger
pipe in horizontal runs
of exhaust pipe.
31-5000728 Rev. 0
TYPICAL EXHAUST PIPE CONNECTIONS IN UPFLOW DIRECT OR
NON-DIRECT VENT APPLICATIONS
Pipe size determined in Table 5
2"
EXHAUST
DO NOT transition
from smaller to larger
pipe in horizontal runs
of exhaust pipe.
* When transitioning up in pipe size, use the shortest length of 2" PVC pipe possible.
NOTE: Exhaust pipe and intake pipe must be the same diameter.
APPLICATIONS (RIGHT-HAND DISCHARGE SHOWN)
12" max.
2"
EXHAUST
DO NOT transition
from larger to smaller
pipe in horizontal runs
of exhaust pipe.
* When transitioning up in pipe size, use the shortest length of 2" PVC pipe possible.
NOTE: Exhaust pipe and intake pipe must be the same diameter.
2"
2"
2"
2"
or
Figure 23.
2"
or
2"
3"
TRANSITION
2"
2"
*2"
*2"
EXHAUST
.
EXHAUST
Figure 24.
Page 29
3"
or
TRANSITION
*2"
045/070 Only
1-1/2"
TRANSITION
2"
6"
MINIMUM
NOTE: 1-1/2" Vent
Pipe Diameter Allowed
Only on 045/070 Units
1-1/2"
or
TRANSITION
2"
2"
EXHAUST
45°
45°
MAX
MAX
SIDE VIEW