Command:
1FH 80H 60H 6FH 00H 6EH
Response: At the time of a success
7FH 60H 80H 61H 03H DATA00 DATA01 DATA02 CKS
Data Portion Contents
-------------------------------------------------------------------
DATA00
Audio1
01H-0CH : Visual Input Data
DATA01
Audio2
01H-0CH : Visual Input Data
DATA02
Audio3
01H-0CH : Visual Input Data
Visual Input Data
01H : VIDEO1*#
02H : VIDEO2*#
03H : VIDEO3*
04H : DVD/HD1*
05H : DVD/HD1#
05H : PC1*
06H : PC2*
06H : DVD/HD2*#
07H : PC/RGB*#
0AH : DVD (DVD1)*
0CH : HD2*
0DH : DVD2*
0EH : PC3*
0EH : DVD/HD3 (HDMI)#
0FH : DVD3 (SCART3)*
1AH : DVD/HD4 (HDMI)#
* PX-42VM4/42VP4/42VP4D/42VM5/42VP5/42VR5/42XM2/42XM3/42XM4/42XM5
* PX-50XM3/50XM4/50XM5/50XM6
* PX-61XM2/61XM3/61XM4/60XM5
# PX-42XR4/42XR5/50XR5/50XR6/61XR4/60XR5
046. FAILURE MODE REQUEST
**********************************************************************
Function:
This command inquires the detection of any failures within the plasma.
Command:
1FH 80H 60H 3FH 00H CKS
Response: At the time of a success
7FH 60H 80H 3FH 02H DATA00 DATA00 CKS
Data Portion Contents
-------------------------------------------------------------------
DATA00
Failure Mode
Bit 0 : PDP MODULE
0 : Abnormal
1 : Normal
Bit 1 : fixed (backup)
Bit 2 : TEMPERATURE
0 : Abnormal
1 : Normal
Bit 3 : FAN
0 : Abnormal

Advertisement