Download Print this page

NEC PlasmaSync 42VM5 Supplementary Manual page 22

Plasma
Hide thumbs Also See for PlasmaSync 42VM5:

Advertisement

1 : Normal
Bit 4 : TEMPERATURE SENSOR
0 : Abnormal
1 : Normal
Bit 5 : fixed (backup)
Bit 6 : fixed (backup)
Bit 7 : fixed (backup)
DATA01
Failure Mode 2
Bit 0-7 : 1:fixed (backup)
052. RUNNING SENSE
**********************************************************************
Function:
This command acquires the operation mode of the plasma.
Command:
1FH 80H 60H 88H 00H CKS
Response: At the time of a success
7FH 60H 80H 88H 01H DATA CKS
Data Portion Contents
-------------------------------------------------------------------
DATA
Status of operation
Bit 7 : Fixed
0 = No execution(Normal condition)
Bit 6 : Fixed
0 = No execution(Normal condition)
Bit 5 : Fixed
0 = No execution(Normal condition)
Bit 4 : Fixed
0 = No execution(Normal condition)
Bit 3 : Fixed
0 = No execution(Normal condition)
Bit 2 : Power Status
0 = Power On
1 = Power Off (Standby)
Bit 1 : Fixed
1 = -
Bit 0 : Fixed
1 = -
056. MULTI MODE SELECT
**********************************************************************
Function:
This command selects the video wall configuration of the plasma.
Command:
DFH 80H 60H 03H 03H DATA00 DATA01 DATA02 CKS
Data Portion Contents
-------------------------------------------------------------------
DATA00
SCREEN DIVIDER SETTING
01H : Single mode

Advertisement

loading