SD-AT50
IC701 RH-iX0564AW00: System Microcomputer (IX0564AW) [Serial No. 208XXXXX Only]
IC701 RH-iX0564AWZZ: System Microcomputer (IX0564AW) [Serial No. 209XXXXX~]
Pin No.
Port Name
1
D3
2*
D4
3
D5
4
D6/CNTR0
5
D7/CNTR1
6
P20/SCK
7
P21/SOUT
8
P22/SIN
9
RESET
10
CNVSS
11
XOUT
12
XIN
13
VSS
14
VDD
15
VDCE
16
P30/INT0
17
P31/INT1
18
AIN0/CMP0-
19
AIN1/CMP0+
20
AIN2/CMP1-
21
AIN3/CMP1+
22
P00
23
P01
24
P02
25
P03
26
P10
27
P11
28
P12
29
P13
30
D0
31
D1
32
D2
In this unit, the terminal with asterisk mark (*) is (open) terminal which is not connected to the outside.
Terminal Name
Input/Output
A/D_RESET
Output
N.C.
Output
SP_RLY
Output
BASS_SW
Output
AC_DETECT
Input
AMP_CLK
Input
AMP_SIN
Output
AMP_SOUT
Input
RESET
Input
CNVSS
Input
XOUT
Output
XIN
Input
VSS
Input
VDD
Input
VDCE
Input
AMP_INT
Output
POWER_ON
Input
+B_CHECK
Input
PROTECT
Input
FAN_CHK
Input
FAN_LOCK
Input
F_S_MUTE
Output
C_S_MUTE
Output
S_S_MUTE
Output
W_S_MUTE
Output
AMP_STB
Input
Input
SYS_STOP
Input
OFF_SET
Input
UNSW_CHK
Input
POWER
Output
-B_CONT
Output
Output of 1 bit AMP∆∑ IC reset control.
"H" output : normal operation, reset when switching from "L" to "H".
Open terminal. "L" is output, PWB is open.
Speaker relay output. (For all the speakers)
"H" output : relay ON, electric conduction, "L" output : relay OFF
Output for controlling the gain of SUBWOOFER amp.
"H" output : BASS OFF, "L" output : BASS ON
Power failure check with the voltage after the AC rectification.
Normal : "L", power failure detection when switching from "L" to "H".
Clock input for communication with the system microcomputer.
Serial auto send/receive.
Data output to the system microcomputer. Serial auto send/receive.
Data input from the system microcomputer. Serial auto send/receive.
Reset input for this microcomputer. Active "L".
0 V (GND).
Reference oscillation output for this microcomputer.
2 MHz ceralcok connection.
Reference oscillation input for this microcomputer.
2 MHz ceralcok connection.
GND terminal.
Positive power supply terminal.
Control of the operation and stop of voltage drop detect circuit.
Used in the stop status (connected to GND).
Communication request signal to the system microcomputer.
Request when switching from "H" to "L".
SW input for POWER ON/OFF test mode.
"H" : normal status, "L" : TEST mode ON/OFF
Power rise monitoring input.
Decision of the reset timing of 1 bit AMP.
A/D import, system abnormality detect input.
A/D import, FAN motor rotation detect input.
A/D import, FAN motor lock detect input.
Front speaker S-MUTE output.
"H" output : MUTE-ON, "L" output : MUTE-OFF.
Center speaker S-MUTE output.
"H" output : MUTE-ON, "L" output : MUTE-OFF.
Surround speaker S-MUTE output.
"H" output : MUTE-ON, "L" output : MUTE-OFF.
Subwoofer speaker S-MUTE output.
"H" output : MUTE-ON, "L" output : MUTE-OFF.
Communication request signal from the system microcomputer.
Request when switching from "H" to "L".
PULL_UP
Power failure detect input. This microcomputer switches to the backup mode.
Normal : "H", power failure detection when switching from "H" to "L".
Abnormality detection output of 1 bit AMP∆∑ IC output offset voltage.
L : abnormal
Power rise timing control. The power is not risen in "L".
Output of power supply control.
"L" output : POWER ON, "H" output : POWER OFF.
Control output for - B power supply control relay of 1 bit AMP section.
"L" output : relay ON, -B supply "H" output : relay OFF