Siemens SITRANS LG270 Operating Instructions Manual page 17

Profibus pa rod and cable probe
Table of Contents

Advertisement

Measuring range
Pressure
Bypass tubes
PBD-51041506
Fig. 8: Mounting of the sensor with inflowing medium
The reference plane for the measuring range of the sensors is the
sealing surface of the thread or flange.
Keep in mind that a min. distance must be maintained below the refer-
ence plane and possibly also at the end of the probe - measurement
in these areas is not possible (dead zone). The length of the cable
can be used all the way to the end only when measuring conductive
products. These dead zones for different mediums are listed in chap-
ter "Technical data". Keep in mind for the adjustment that the default
setting for the measuring range refers to water.
The process fitting must be sealed if there is gauge or low pressure in
the vessel. Before use, check if the seal material is resistant against
the measured product and the process temperature.
The max. permissible pressure is specified in chapter "Technical
data" or on the type label of the sensor.
Standpipes or bypass tubes are normally metal tubes with a diameter
of 30 ... 200 mm (1.18 ... 7.87 in). Up to a diameter of 80 mm (3.15
in) such a tube corresponds to a coax measuring probe. Lateral inlets
in bypass tubes do not influence the measurement.
Measuring probes can be mounted in bypass tubes up to DN 200.
For bypass tubes, select the probe length such that the dead zone
of the probe is above and below the lower lateral filling openings of
the bypass tube. You can thus measure the complete range of the
medium in the bypass tube (h). When designing the bypass tube,
keep the dead zone of the probe in mind and select the length of the
bypass tube above the upper lateral filling opening accordingly.
SITRANS LG270 - Operating Instructions
17

Advertisement

Table of Contents
loading

Table of Contents