8

Troubleshooting

8.1

LED indications

LED indication
Red
No LED light
Green (but no DYNlink
output detected)
Weak lights
2TLC172163M0201 Rev.F
Probable cause
Button actuated/pressed
+24 VDC connected to
DYNlink signal input
Loss of power supply
Defective DYNlink signal
input to unit
Unit is defective
Action
Turn the button clockwise and pull
it up.
Check if there is +24 VDC on
DYNlink signal input. If yes, check
cable connections or the unit
before.
Check +24 VDC / 0 VDC power
supply.
Check the DYNlink input or the unit
before.
Replace the unit.