2.
TECHNICAL SPECIFICATIONS
Manifold Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1750 psi . . . . . . . . . .1850 psi
Effective Cleaning Power . . . . . . . . . . . . . . . . . . . . . . . . . .1750 psi . . . . . . . . . .1850 psi
Water Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .480 l/h . . . . . . . . . . .600 l/h
Motor Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2180 W . . . . . . . . . . .2285 W
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230 V . . . . . . . . . . . .230 V
Motor rpm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2800 . . . . . . . . . . . . .2800
Max Inlet Temp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
Trolley Included . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Yes . . . . . . . . . . . . . .Yes
Hose Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7.4 m . . . . . . . . . . . .7.4 m
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 kg . . . . . . . . . . . .31 kg
3.
SETUP & ASSEMBLY
WARNING! Ensure the washer is not connected to the mains power before continuing; or when changing any accessories,
performing any maintenance, or servicing. The water supply hose should be reinforced and have an internal diameter of 13mm (1/2”).
p
The minimum water supply rate should be 500 l/h for PC2275, and 620 l/h for PC2285.
3.1.
Preliminary checks and advice
3.1.1.
Before starting ensure the water intake is correctly connected. Dry running can seriously damage the unit.
3.1.2.
Check the inlet filter is clean; pump delivery and pressure will be reduced if blocked. Never use the machine without a filter (fig 1).
3.1.3.
The unit is filled with oil and sealed at the factory. There is no need to check the oil level.
3.2.
Setup
3.2.1
Insert the lance into the trigger assembly and twist to secure (fig 2).
3.2.2.
Connect the trigger assembly to the high pressure hose and tighten with a 17mm spanner (fig 3).
3.2.3.
Connect the high pressure hose to the top water outlet on the washer (fig 4).
3.2.4.
Connect the water supply hose to the bottom water inlet on the washer (fig 4).
3.2.5.
Assemble the handle as follows referring to (fig 5):
a) Place pipes D into handle grip A (Each grip has one locating plug which must pass through the locating hole in the pipe).
b) Fit grip B and secure with the 8 nuts and bolts provided (C).
c) Fit cones F and lock rings E over the pipes. Insert the pipes in the tank-frame G, and tighten the lock rings.
fig 1
fig 4
4.
OPERATION
IMPORTANT! The motors in these washers are 230V/2.18kW (PC2275) and 230V/2.29kW (PC2285) and at normal mains
voltage will start within the capacity of a 13 amp fused circuit.
p
Certain local conditions relating to electrical supply in the UK can result in the voltage varying between a low of 216 volts
and a high of 253 volts. At such times of fluctuating voltage the 13 amp fuse in the washer plug may blow. This is normal
and is not a fault with the washer. However if it happens regularly we recommend that you consult an electrician with a
view to installing a 30 amp supply, with contact breaker, to avoid the inconvenience of frequent fuse replacement.
Extension leads MUST NOT be used to connect the washer to a 13 amp supply as the resulting voltage drop will cause the
13 amp fuse to blow.
PC2275
C . . . . . . . . . . . . .60
O
HIGH
PRESSURE
OUTLET
WATER
INLET
PC2285
C
O
fig 2
fig 5
fig 3
PC2275 & PC2285 - 0061 - (3) - 060300

Advertisement

loading

This manual is also suitable for:

Pc2285