Siemens SIMATIC NET RUGGEDCOM RS1600T Installation Manual

Ethernet switches

Advertisement

Quick Links

Edition
11/2022
Installation Manual
SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM RS1600T
https://www.siemens.com/ruggedcom

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET RUGGEDCOM RS1600T

  • Page 1 Edition 11/2022 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RS1600T https://www.siemens.com/ruggedcom...
  • Page 2 Preface Introduction Installing Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RS1600T Communication Ports Technical Specifications Installation Manual Certification 11/2022 C79000-G8976-1015-04...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................vi Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Decommissioning and Disposal ................4 Cabling Recommendations ..................4 1.4.1...
  • Page 5 Table of Contents Copper Ethernet Port Specifications ..............21 Fiber Optic Ethernet Port Specifications ............... 22 Operating Environment ..................22 Mechanical Specifications ..................23 Dimension Drawings ................... 23 Certification ......................... 27 Approvals ......................27 6.1.1 UKCA ........................27 6.1.2 CSA ........................27 6.1.3 European Union (EU) ..................
  • Page 6: Preface

    SIMATIC NET Glossary The SIMATIC NET Glossary describes special terms that may be used in this document. The glossary is available online via Siemens Industry Online Support (SIOS) at: https://support.industry.siemens.com/cs/ww/en/view/50305045 Accessing Documentation The latest user documentation for RUGGEDCOM RS1600T is available online at https://support.industry.siemens.com.
  • Page 7: Warranty

    Preface Warranty Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 8: Contacting Siemens

    Call a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit https://w3.siemens.com/aspa_app/?lang=en. Mobile App Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: •...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RS1600T Installation Manual, 11/2022, C79000-G8976-1015-04...
  • Page 10: Introduction

    Introduction The RUGGEDCOM RS1600T provides substation hardened, fully managed, Ethernet switches specifically designed to operate reliably in electrically and environmentally harsh environments. The RUGGEDCOM RS1600T’s Zero-Packet-Loss™ technology provides a high level of immunity to electromagnetic interference (EMI) and heavy electrical surges typical of environments found in electric utility substations, industrial plant floors or in curb side traffic control cabinets.
  • Page 11: Description

    Introduction 1.2 Description • Meets IEEE 1613 Class 2 (electric utility substations) • Exceeds IEC 61850-3 (electric utility substations) • Exceeds IEC 61800-3 (variable speed drive systems) • Exceeds IEC 61000-6-2 (generic industrial) • Exceeds NEMA TS-2 (traffic control equipment) • -40 to 85 °C (-40 to 185 °F) operating temperature (no fans) •...
  • Page 12 Introduction 1.2 Description Front Rear Port Status LED RESET Button 100Base-FX Fiber Optic Ethernet Ports 10/100Base-TX Copper Ethernet Ports Power LEDs Power Terminal Block Chassis Ground Connection Failsafe Alarm Relay RS232 Serial Console Port (DB9) Figure 1.1 Front and Rear Panels Power LEDs Illuminate when power is being supplied to the device by either PS1 (Power Supply 1) or PS2 (Power Supply 2).
  • Page 13: Decommissioning And Disposal

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 14 Introduction 1.4.1 Supported Fiber Optic Cables Cable Type Wavelength (nm) Modal Bandwidth Distance (m) (MHz·km) 100Base-FX 1000Base-SX 10GBase-SR OM1 (62.5/125) — 1300 2000 — — OM2 (50/125) — 1300 2000 — — OM3 (50/125) 1500 — 1300 2000 — — OM4 (50/125) 3500 —...
  • Page 15 Introduction 1.4.1 Supported Fiber Optic Cables RUGGEDCOM RS1600T Installation Manual, 11/2022, C79000-G8976-1015-04...
  • Page 16: Installing Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 17: General Procedure

    Visually inspect each item in the package for any physical damage. Verify all items are included. Note If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM RS1600T is designed for maximum mounting and display flexibility.
  • Page 18: Mounting The Device To A Rack

    Installing Device 2.3.1 Mounting the Device to a Rack 2.3.1 Mounting the Device to a Rack For rack mount installations, the RUGGEDCOM RS1600T can be equipped with rack mount adapters pre-installed. Note The chassis features multiple mounting holes, allowing the rack mount adapters to be installed up to 25 mm (1 in) from the face of the device.
  • Page 19: 2.3.3 Mounting The Device To A Panel

    Installing Device 2.3.3 Mounting the Device to a Panel To mount the device to a DIN rail, do the following: Align the adapters with the DIN rails and slide the device into place. Panel/DIN Rail Adaptor DIN Rail Screw Figure 2.2 DIN Rail Mounting Install one of the supplied screws on either side of the device to secure the adapters to the DIN rails.
  • Page 20: Connecting Power

    Installing Device 2.4 Connecting Power Screw Panel/DIN Rail Adapter Figure 2.3 Panel Mounting Install the supplied screws to secure the adapters to the panel. Connecting Power The RUGGEDCOM RS1600T supports single or dual redundant high AC, high DC and/or low DC power supplies. The use of two power modules is recommended to provide redundancy and load balancing.
  • Page 21: 2.4.1 Connecting Ac Power

    Installing Device 2.4.1 Connecting AC Power • Use minimum #16 gage wiring when connecting terminal blocks. • A circuit breaker is not required for 12, 24 or 48 VDC rated power supplies. • It is recommended to provide a separate circuit breaker for each power supply module.
  • Page 22: 2.4.2 Connecting Dc Power

    Installing Device 2.4.2 Connecting DC Power Braided Ground Cable Figure 2.4 Terminal Block Wiring Connect the negative wire from the power source to the negative/neutral (-/N) terminal on the terminal block. Using a braided wire or other appropriate grounding wire, connect the surge ground terminal to the chassis ground connection.
  • Page 23: 2.4.3 Wiring Examples

    Installing Device 2.4.3 Wiring Examples Chassis Ground Terminal Figure 2.5 Terminal Block Wiring Connect the negative wire from the power source to the negative/neutral (-/N) terminal on the terminal block. Using a braided wire or other appropriate grounding wire, connect the surge ground terminal to the chassis ground connection.
  • Page 24: Connecting The Failsafe Alarm Relay

    Installing Device 2.5 Connecting the Failsafe Alarm Relay Figure 2.8 Dual AC Power Supply Figure 2.9 Dual DC Power Supply Figure 2.10 Dual AC/DC Power Supply Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions. The NO (Normally Open) contact is closed when the unit is powered and there are no active alarms.
  • Page 25 Installing Device 2.5 Connecting the Failsafe Alarm Relay For more information, refer to the "RUGGEDCOM RS1600T User Guide" for the RUGGEDCOM RS1600T. The following shows the proper relay connections. Normally Closed Terminal Common Terminal Normally Open Terminal Figure 2.11 Failsafe Alarm Relay Wiring RUGGEDCOM RS1600T Installation Manual, 11/2022, C79000-G8976-1015-04...
  • Page 26: Device Management

    Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RS1600T console and Web interfaces on the device. For more detailed instructions, refer to the "RUGGEDCOM RS1600T User Guide" for the RUGGEDCOM RS1600T. Serial Console Port Connect a PC or terminal directly to the serial console port to access the boot-time control and RUGGEDCOM ROS console interface.
  • Page 27: Resetting The Device

    Device Management 3.2 Resetting the Device IP address. For more information about available ports, refer to "Communication Ports" (Page 19). Resetting the Device The RUGGEDCOM RS1600T can be reset (rebooted) using the RESET button. The RESET button is recessed and can only be reached using a pin or small screwdriver. To reset the device, quickly press and release the RESET button with a pin.
  • Page 28: Communication Ports

    Communication Ports The RUGGEDCOM RS1600T can be equipped with various types of communication ports to enhance its abilities and performance. To determine which ports are equipped on the device, refer to the factory data file available through RUGGEDCOM RS1600T. For more information on how to access the factory data file, refer to the "RUGGEDCOM RS1600T User Guide"...
  • Page 29: Fiber Optic Ethernet Ports

    Communication Ports 4.2 Fiber Optic Ethernet Ports The following is the pin-out for the RJ45 male connector:   Name Description Receive Data+ Receive Data- Transmit Data+ Reserved (Do Not Connect) Figure 4.2 RJ45 Ethernet Port Pin Reserved (Do Not Connect) Configuration Transmit Data- Reserved (Do Not Connect) Reserved (Do Not Connect) Case...
  • Page 30: Technical Specifications

    Technical Specifications The following sections provide important technical specifications related to the device and available modules: Power Supply Specifications Input Range Maximum Power Internal Fuse Isolation Power Supply Type Rating Minimum Maximum Consumption 12–24 VDC 10 VDC 36 VDC 6.3 A(F) 1.5 kVDC 24 VDC 18 VDC...
  • Page 31: Fiber Optic Ethernet Port Specifications

    Technical Specifications 5.4 Fiber Optic Ethernet Port Specifications Maximum Speed ConnectorDuplex Cable Type Wiring Standard Isolation Distance FDX/ 10/100Base-TX RJ45 > Category 5 TIA/EIA T568A/B 100 m (328 ft) 1.5 kV Auto-negotiating. Shielded or unshielded. Auto-crossover and auto-polarity. Typical distance. Dependent on the number of connectors and splices. RMS 1 minute.
  • Page 32: Mechanical Specifications

    Technical Specifications 5.6 Mechanical Specifications Mechanical Specifications Weight 10 lb (4.5 Kg) Ingress Protection IP30 Enclosure 18 AWG Galvanized Steel Dimension Drawings Note All dimensions are in millimeters, unless otherwise stated. 438.2 Figure 5.1 Overall Dimensions RUGGEDCOM RS1600T Installation Manual, 11/2022, C79000-G8976-1015-04...
  • Page 33 Technical Specifications 5.7 Dimension Drawings 464.6 479.4 Figure 5.2 Rack Mount Dimensions RUGGEDCOM RS1600T Installation Manual, 11/2022, C79000-G8976-1015-04...
  • Page 34 Technical Specifications 5.7 Dimension Drawings 486.4 476.3 Figure 5.3 Panel and DIN Rail Mount Dimensions RUGGEDCOM RS1600T Installation Manual, 11/2022, C79000-G8976-1015-04...
  • Page 35 Technical Specifications 5.7 Dimension Drawings RUGGEDCOM RS1600T Installation Manual, 11/2022, C79000-G8976-1015-04...
  • Page 36: Certification

    Approvals This section details the standards to which the RUGGEDCOM RS1600T complies. Note All relevant certificates and test reports are available on Siemens Industry Online Support [https://support.industry.siemens.com]. 6.1.1 UKCA This device is certified for use in Great Britain and bears the United Kingdom Certified Assessed (UKCA) marking.
  • Page 37: European Union (Eu)

    Certification 6.1.3 European Union (EU) 6.1.3 European Union (EU) This device is declared by Siemens Canada Ltd. to comply with essential requirements and other relevant provisions of the following EU directives: • EN 62368-1 Information Technology Equipment – Safety – Part 1: General Requirements •...
  • Page 38: Fda/Cdrh

    Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health 6.1.6 ISED This device is declared by Siemens Canada Ltd. to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) 6.1.7...
  • Page 39: Rohs

    Support at https://support.industry.siemens.com/cs/ww/en/view/89855782. 6.1.9 RoHS This device is declared by Siemens Canada Ltd. to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: China RoHS 2 •...
  • Page 40 Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severity Levels IEC 61000-4-6 Induced Signal Ports 10 V (Conducted) DC Power Ports 10 V AC Power Ports 10 V Earth 10 V Ground Ports IEC 61000-4-8 Magnetic Field Enclosure Ports 40 A/m Continuous,  ...
  • Page 41 Certification 6.2 EMC and Environmental Type Tests Description Test Levels DC Power Ports ± 4 kV AC Power Ports ± 4 kV Earth Ground Ports ± 4 kV Oscillatory Signal Ports 2.5 kV Common mode @ 1MHz DC Power Ports 2.5 kV Common and Differential Mode @ 1MHz AC Power Ports 2.5 kV Common and Differential Mode @ 1MHz HV Impulse...
  • Page 42 For more information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens Canada Ltd. Digital Industries Process Automation 300 Applewood Crescent Concord, Ontario, L4K 4E5 Canada © 2022 Siemens Canada Ltd. Subject to change...

Table of Contents