Siemens SIMATIC FDE Operating Instructions Manual

Siemens SIMATIC FDE Operating Instructions Manual

Hide thumbs Also See for SIMATIC FDE:

Advertisement

Quick Links

SIMATIC FDE Gateway
FDE
SIMATIC FDE Gateway
Operating Instructions
02/2023
A5E52308942-AB
Preface
Siemens Industry Online
Support
Introduction
Overview of the technical
documentation
Installing and connecting a
device
Software and
commissioning
Technical specifications
Technical specifications
Dimension drawings
1
2
3
4
5
6
7
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC FDE

  • Page 1 SIMATIC FDE Gateway Preface Siemens Industry Online Support Introduction Overview of the technical documentation SIMATIC FDE Gateway Installing and connecting a device Software and commissioning Operating Instructions Technical specifications Technical specifications Dimension drawings 02/2023 A5E52308942-AB...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    A prerequisite for understanding this manual is knowledge of how to use a PC. Basic knowledge of automation technology as well as IoT technologies is also recommended. Scope of this document These operating instructions apply to the SIMATIC FDE Gateway device. MLFB 6ES7617-0AA00-0AB0 FDE conventions...
  • Page 4: Table Of Contents

    Table of contents Preface ..............................3 Siemens Industry Online Support ......................6 Introduction ............................7 Security information ......................7 IT security on the northbound side ..................7 Overview of the technical documentation .................... 8 Brownfield Connectivity Gateway ..................8 SIMATIC products ........................ 8 SINAMICS products ......................
  • Page 5 6.2.1 Electromagnetic Compatibility industrial area +A1:2011 ............. 49 6.2.2 ESD guideline ........................49 Technical specifications ........................52 General technical specifications ..................52 Ambient conditions......................53 Dimension drawings ..........................54 Dimension drawings ......................54 SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 6: Siemens Industry Online Support

    For answers and solutions concerning automation technology. • mySupport Your personal working area in Industry Online Support for messages, support queries, and configurable documents. This information is provided by the Siemens Industry Online Support in the Internet (https://support.industry.siemens.com). SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 7: Introduction

    Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
  • Page 8: Overview Of The Technical Documentation

    For a detailed BFC Gateway Function Manual, see: Brownfield Connectivity Gateway (https://support.industry.siemens.com/cs/ww/en/view/109801700/) SIMATIC products You can find an overview of the SIMATIC documentation available in Siemens Industry Online Support here: Industry Online Support International (https://support.industry.siemens.com/cs/ww/en/view/109742705) SINAMICS products SIMATIC FDE Gateway enables connection to the following drives: •...
  • Page 9 Parameter list The parameter list contains a detailed description of all parameters, ordered by function. In addition, the parameter list contains function charts with graphical representations of the converter functions. SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 10 SINAMICS V20 frequency converter Operating instructions The operating instructions contain information on the installation, commissioning, operation, and maintenance of the SINAMICS V20 frequency converter. SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 11: Installing And Connecting A Device

    Installing and connecting a device Scope of supply Supplied components The following components are included in the scope of supply of the SIMATIC FDE Gateway with article number 6ES7617-0AA00-0A: • 1 x complete unit SIMATIC FDE Gateway • 1 x 10-pin connecting terminal X4...
  • Page 12: Description

    4.3 Description Description The SIMATIC FDE Gateway is a flexible HW module for brownfield connectivity. The device allows the transfer of data from the field level to an edge device or to the cloud (northbound connection). It connects an RS232/USS device and digital and analog inputs/outputs via MQTT with edge devices and cloud systems.
  • Page 13 • Wi-Fi: Northbound connection or for configuration via a local access point Main characteristics • Comprehensive interface set • CE conformity • Low-limitation, local processing power • Simple installation – plug & play • Open, encrypted Cloud/IoT interface (MQTT 3.1.1) SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 14: Device Design

    Installing and connecting a device 4.4 Device design Device design The following figure shows the design of the SIMATIC FDE Gateway, with interfaces: ① Ethernet interface LAN1: TCP/IP interface ⑥ RESET button ② Ethernet interface LAN2: TCP/IP interface ⑦ Connection for power supply (24 V DC pow- er supply unit) ③...
  • Page 15: Analog Or Digital Input/Output

    For connection to I/O, see section "Connecting interfaces to connecting terminal X4 (Page 21)". Overview of operating modes The LED display signals the following operating modes: Operating mode Color Illuminated green CONFIGURATION Flashing yellow SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 16: Changing The Operating Mode

    Do not dispose of the original packaging. Be sure to pack the device during transport and storage. 4. Check the contents of the packaging and the accessories for completeness and damage. – Device – DC connecting terminal, already plugged into the device. SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 17 Do not expose the device to direct heat radiation from a heater. If condensation occurs, wait about 12 hours or until the device is completely dry before switching it on. 6. Make a note of the device's identification data. SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 18: Installing The Device

    Mounting instructions • The device is only approved for operation indoors. • When installing in a control cabinet, observe the SIMATIC installation guidelines (https://support.industry.siemens.com/cs/ww/en/view/1064706) as well as the relevant DIN/VDE regulations or the respective country-specific regulations. Secure mounting The device is mounted horizontally on a DIN rail with a standard 35 mm profile.
  • Page 19: Connecting The Device

    • If a thunderstorm is approaching, disconnect the device from the electricity supply network in good time. • Do not touch power or transmission cables during a storm. • Maintain sufficient distance from electrical cables, distributors, systems, etc. SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 20 The device may only be connected to a 24 V DC power supply that meets the requirements for safety extra-low voltage (SELV) according to IEC/EN/DIN EN/UL 61010-1. The power supply must meet the requirements of NEC Class 2 or LPS according to IEC/EN/DIN EN/UL 60950-1. SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 21: Connecting Interfaces To Connecting Terminal X4

    DIO H/AI H High/VCC for 24 V configurable digital DI/DO/AI (isolated) DIO L/AI L Low for 24 V configurable digital DI/DO/AI (isolated) RS TXD/A TxD pin for RS232 RS RXD/B RxD pin for RS232 SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 22: Connecting The Power Supply

    In case of voltage peaks on the power supply lines, protective devices in the form of a varistor (MOV) UMOV = U-nom. x 1.2 (BLITZDUCTOR BVT AVD 24 (918 422) or equivalent) must to be used. SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 23: Securing Cables

    Connecting the converter Connect the converter to pins 5–7 of the spring-loaded terminal. You can connect a SIMATIC FDE Gateway to one of the following converters via the RS232 interface on the converter-specific module or control device: • SINAMICS V20 •...
  • Page 24 1) Connect the optical cable (article number: 3RK1922-2BP00) with the optical I/O port interface on the power unit for the RS232 communication. Wiring example The following SINAMICS V20 example shows the wiring between the converter and the SIMATIC FDE Gateway. SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 25 When connecting the converter consider the following in order to achieve better EMC behavior: • Use a shielded cable for RS232 communication between the converter and the device. • Route the signal cable and the electric power cable separately in different cable ducts. SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 26: Software And Commissioning

    The SSID and KEY are specified on the nameplate of the device: The serial number (S), X1, X2, WiFi, SSID and key are device-specific. The first time you log in, a registration window is displayed, prompting you to specify a password: SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 27: Device Configuration

    Click "Sign up". After successful registration you can connect to the device using your password. If the password is lost, the device has to be reset and reconfigured. Device configuration Log on to the device by entering your password: The start page appears. SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 28 5.2 Device configuration Start page The start page provides information on the device and its current settings. ① Menu ② Information about the device ③ Operating mode settings ④ Network settings ⑤ Connectivity settings SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 29: Network Settings

    Manually: The parameters for both LAN ports are entered manually and, if necessary, specified together with the network administrator. The lines with asterisks must be completed. The settings are only applied after a restart. SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 30 Wi-Fi connection and fill out the parameters for the Wi-Fi connection in the Wi-Fi tab. Complete the settings for the Wi-Fi client. Select a Wi-Fi network with good signal strength. During operation, the connection to a cloud/Internet connection can be set. SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 31: Connectivity Settings

    Client ID: Uniquely identifies MQTT clients at the MQTT broker Publish topic name: Each sent MQTT message is assigned to this topic Subscribe topic name: MQTT messages to this Gateway are expected at this topic SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 32 1 second. All other times can be set, for example: 5 s, 10 s, etc. You can find examples of payloads with parameters in section MQTT payload examples (Page 38). SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 33 You can find detailed information on the available parameters, data types, numbers, and indexes in the Product Information for your converter. You can also select a template valid for G120 via "Select template". SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 34 To set the analog input, select the signal type "Analog input" and the desired sensing type (current 0 - 20 mA or voltage 1 - 10 V). To set the digital output, select the signal type "Digital output" and the desired port status (Closed or Open). SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 35 Software and commissioning 5.4 Connectivity settings Correct wiring of inputs and the output are described in the chapter "Digital or analog input, digital output (Page 15)". SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 36 Settings of the Digital_Output application via MQTT protocol A Subscribe topic name is assigned under Connectivity/MQTT. Under this topic you can change the values of the DIGITAL_OUTPUT application, e.g.: Publish desired change to the application DIGITAL_OUTPUT: SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 37 The publish topic name must match the previously set subscribe topic name in the SIMATIC FDE Gateway. The following payload in the JSON format shows how the settings can be changed: "app": "DIGITAL_OUTPUT", "version": "1.0", "parameters": { "VALUE": true The VALUE value can be changed. SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 38: Mqtt Payload Examples

    "app": "USS", "parameters": { "Parameter1": { "value": 315.854, "type": "float" "STATUS": { "value": 0, "type": "int32_t" "STATUS_INFO": { "value": "{}", "type": "string" "TIMESTAMP_MS": { "value": "1663312002231", "type": "string" "READOUT_MS": { "value": 35, "type": "uint32_t" SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 39 "value": "digital_input_signal", "type": "string" "VALUE": { "value": 1, "type": "int8_t" Explanation The value under "VALUE" corresponds to the state of the digital input: • Value: 1: Input voltage. • Value: 0: No input voltage. SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 40 "SIGNAL_NAME": { "value": "analog_input_voltage", "type": "string" "RAW_VALUE": { "value": 4057, "type": "uint32_t" "MA_VALUE": { "value": 20, "type": "float" "MV_VALUE": { "value": 0, "type": "float" Explanation The value under "MA_VALUE" is output directly in mA. SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 41 "type": "string" "RAW_VALUE": { "value": 451, "type": "uint32_t" "MA_VALUE": { "value": 0, "type": "float" "MV_VALUE": { "value": 8185.19, "type": "float" "app": "USS", "parameters": { Explanation The value under "MV_VALUE" is entered directly in mV SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 42: Date And Time Setting

    Date and time setting Date & time The time configured in the device always corresponds to UTC as the primary format. This time can be selected manually or applied from the web browser: SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 43: Factory Settings, System Upgrade

    If the password has been forgotten, it can be reset through a reset to the factory settings. System upgrade Any updated software versions are available in the Sie-Portal (https://sieportal.siemens.com/). You can update the software via the configuration interface: SIMATIC FDE Gateway...
  • Page 44 • Ensure that the device is connected to a stable 24 V power supply. • Do not close or refresh the website. • Ensure that your client is always connected to the SIMATIC FDE Gateway hotspot. Do not leave the area.
  • Page 45: Settings For Operation On The Bfc Gateway

    (only valid for G120). • The BFC Gateway settings and installation are described in the BFCG Function Manual (https://support.industry.siemens.com/cs/ww/en/view/109801700/). • Middleware script must be inserted (internal mapping of the parameter values). SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 46: Settings For Operation On The Industrial Edge Device

    These apps offer solutions for visualizing data and machine tool-related KPIs which provide information about the production and machines states. The Siemens Industrial Edge Hub (https://iehub.eu1.edge.siemens.cloud/) platform also offers many pre-built apps. For example, the apps "Analyze MyDrives /Edge (https://support.industry.siemens.com/cs/ww/en/view/109800585)" or "Predictive Service Analyzer - Converter"...
  • Page 47: Settings For Operation In Mindsphere

    5.10 Settings for operation in MindSphere The Siemens IoT-as-a-service solution MindSphere saves operating data and makes them accessible through digital applications so that you can make decisions on the basis of valuable factual information. One of these apps is the Predictive Service Assistance app which offers access via your tenant to all relevant service and asset data of the drive systems, such as pumps and fans.
  • Page 48: Technical Specifications

    TÜV (German Technical Inspectorate) Rheinland Software license agreements If the device is supplied with installed software, you must observe the corresponding license agreements. 6.1.3 WEEE guideline WEEE mark (European Union) Disposal instructions; observe local regulations. SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 49: Directives And Declarations

    The consequences are unpredictable, and range from unforeseeable malfunctions to total failure of the machine or plant. It is essential to avoid touching components directly. Make sure that personnel, workstations, and packaging are properly grounded. SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 50 If no grounding is available, then no equipotentiality can be achieved. Electrostatic charges are not discharged and damage to the ESD may occur. Protect yourself against electrostatic discharging. When handling ESDs, make sure that personnel and workstations are properly grounded. SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 51 In this way, the discharge energy does not reach and damage any sensitive components. – Discharge your body electrostatically before taking module measurements by touching grounded metallic objects. Only use grounded measuring devices. SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 52: Technical Specifications

    If there are voltage peaks on the power supply lines, use a protective device in the form of a varistor (MOV) UMOV = Urated x 1.2 (BLITZDUCTOR BVT AVD 24 (918 422) or compatible). SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 53: Ambient Conditions

    5 … 8.4 Hz: Deflection 3.5 mm • 8.4 … 500 Hz: Acceleration 9.8 m/s Shock resistance, tested according to IEC 60068-2-27 150 m/s , 11 ms • Operation 250 m/s , 6 ms • Transport/storage SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...
  • Page 54: Dimension Drawings

    Dimension drawings Dimension drawings The following figures show the dimension drawings of the FDE Gateway device. All dimensions are in mm. SIMATIC FDE Gateway Operating Instructions, 02/2023, A5E52308942-AB...

Table of Contents