Disposal Of Packing; Positioning - Electrolux SkyLine PremiumS 6GN2/1 Installation Manual

Electrical combi oven, touch and digital
Table of Contents

Advertisement

Required
entrance
6 GN
6 GN
dimen-
1/1
2/1
sions
mm
850
1046
x
33"
41" 3/
inch
15/32
16
E.4.2

Disposal of packing

The packing must be disposed of in compliance with the
current regulations in the country where the appliance is used.
All the packing materials are environmentally friendly.
They can be safely kept, recycled, or burned in an appropriate
waste incineration plant. Recyclable plastic parts are marked
as follows:
Polyethylene
• Outer wrapping
• Instructions bag
Polypropylene
• Straps
Polystyrene foam
• Corner protectors
The parts in wood and cardboard can be disposed of,
respecting the current regulations in the country where the
appliance is used.
E.4.3

Positioning

For the overall space required and connection dimensions,
refer to the installation diagrams;
NOTE!
The appliance is not suitable for built-in installation.
When positioning the appliance keep in mind the following
minimum distances:
Minimum distances for positioning
normal working
right / left / rear distance 50 mm
work close to
left side distance 350 mm to 500 mm
heat source
service
left side distance 500 mm
conditions
• All appliance sides must remain at 50 mm from any surface.
50mm/2"
If it's necessary to carry out maintenance works on the
appliance, slide it forwards.
22
Appliance models
10 GN
10 GN
20 GN
20 GN
1/1
2/1
1/1
850
1046
925
1125
33"
41" 3/
36"
15/32
16
27/64
27/64
50mm/2"
50mm/2"
2/1
44"
In all models but especially in 20 grids models when possible
leave a space of at least 500 mm between the left side of the
appliance and the other surfaces to enable maintenance
operations.
500mm/
20"
• The left gap must be a minimum of 350 mm if heat sources
are acting on the left side of the appliance.
If it is not possible to keep the left side of the appliance a
sufficient distance away from heat sources, a heat shield
can reduce thermal loads (see accessories catalogue).
• If steam from the ventilation pipe cannot be directed into an
exhaust hood or a ventilating ceiling, there must be at least
500 mm clearance space above the device.
• Position the appliance on a flat surface.
If necessary, adjust the height of the worktop by means of
the adjustable feet (if available).
50mm/2"
50mm/2"
50mm/2"
50mm/2"
50mm/2"
≥ 350mm
14"
min. 500 mm

Hide quick links:

Advertisement

Table of Contents
loading