Flue Terminal Positions; Inspection Apertures - Bosch Condens 8300i W Installation And Maintenance Instructions Manual

Wall mounted gas condensing boiler
Table of Contents

Advertisement

Flue gas routing
4.3

Flue terminal positions

n
f
c
Fig. 5
Flue terminal positions
D
Door
I
Mechanical air inlet
M
Gas meter
T
Flue terminal
W
Window
Ref.
Item
a
Below eaves, balconies and other projections (Appliances over 50MJ/h)
b
From the ground, above a balcony or other surface
c
From a return wall or external corner
d
From a gas meter
e
From an electricity meter or fusebox/breaker panel
f
From a drain pipe or soil pipe
g
Horizontally from any building structure or obstruction facing a flue terminal
h
From any other flue terminal, cowl or combustion air intake
j
Horizontally from any opening window, door, non-mechanical air inlet or other opening into a building with the exception of
sub-floor ventilation
k
From a mechanical air inlet including a spa blower
n
Vertically below an opening window, non-mechanical air inlet or any other opening into a building with the exception of sub-
floor ventilation
Table 5
• The location of the flue terminal must comply with the clearances
shown on this page.
If you are unsure about clearances not indicated here, in general refer
to AS/NZ 5601 or your local authority.
• All measurements are the minimum clearances required.
• Terminals must be positioned so to avoid combustion products
entering the building.
10
j
j
j
h
W
D
k
I
k
a
T
h
e
e
h
d
P
d
T
M
g
4.4

Inspection apertures

It must be possible to clean flue systems easily and safely. It must be
possible:
• to check the cross-section and tightness of the pipework.
• to check the required cross-section between the flue and duct
(secondary ventilation) for safe operation of the combustion system,
and to clean it.
▶ Observe local standards and regulations.
Condens 8300i W – 6721841533 (2022/12)
c
g
b
T
6720644146-07.1J
Min. Clearance
(in mm)
300
300
300
1000
500
75
500
300
300
1000
1000