Menu 3: basic settings
▶ Press the ( key and * key simultaneously until the display shows
L.1.
▶ Press the  key repeatedly until L.3 appears.
▶ To confirm the selection: press OK key.
▶ Selecting and setting the service function.
Service function
3-b1 Maximum approved heating capacity
3-b2 Time interval between stopping and
starting the burner in heating mode
3-b3 Temperature differential for restarting
the burner
3-C1 Maximum released DHW output
3-C2 Circulating pump
3-C3 DHW circulation pump (number of
starts)
3-C7 Start thermal disinfection manually
3-CA DHW Mode
3-d1 Pump characteristic
3-d2 Pump control mode
3-d3 Min. output of the heating pump
3-d4 Max. output of the heating pump
3-d6 Overrun time of the heating pump in
heating mode
Table 19 Menu 3: basic settings
Condens 8300i W – 6721841533 (2022/12)
The factory settings are depicted as highlighted in the following table.
Settings/adjustment range
• 50 ... 100 % (depending on the appliance output) ▶ Set the heating capacity in percent.
• 3 ... 10 ... 60 minutes
• -15 ... -6 ... -2 K ( °C)
• 50 ... 100 %
• OFF
• ON
• 1: 1 × 3 min/h
• 2: 2 × 3 min/h
• 3: 3 × 3 min/h
• 4: 4 × 3 min/h
• 5: 5 × 3 min/h
• 6: 6 × 3 min/h
• 7: permanent
• OFF
• ON
• 0: Comfort mode, in comfort mode, the DHW
cylinder is reheated when the temperature
differential is 5 K (5 °C) or more.
• 1: ECO mode, in ECO mode, the DHW cylinder is
reheated when the temperature differential is
10 K (10 °C) or more.
• 0: Pump output proportional to the heat output
• 1: constant pressure 150 mbar
• 2: constant pressure 200 mbar
• 3: constant pressure 250 mbar
• 4: constant pressure 300 mbar
• 5: constant pressure 350 mbar
• 6: constant pressure 400 mbar
• OFF
• ON
• 10 ... 100 %
• 10 ... 100 %
• 1 ... 2 ... 60 minutes
• 24 hours
Settings in the service menu
Remark/restriction
▶ Measure the gas rate.
▶ Compare the measurement with the setting
tables ( page 55). Correct the setting in
the case of any deviation.
The time interval determines the minimum
waiting time between switching off the burner
and switching it back on (standby period).
The difference between the current flow
temperature and the set flow temperature until
the burner is switched on.
Only available with DHW circulation pump ON.
With activated thermal disinfection, the DHW
cylinder is heated up to the set temperature set
for the thermal disinfection and kept at this
temperature for 20 min.
In comfort mode there is a higher DHW output.
▶ In order to save energy and reduce any flow
noise, set a low pump curve
( Chapter 13.5, page 55).
• ON: Save energy: intelligent shutdown of
heating pump for heating systems with
weather-compensated controller. The
heating pump is only switched on if required.
Pump output at minimum heat output. Only
available with pump characteristic 0.
Pump output at maximum heat output. Only
available with pump characteristic 0.
The pump overrun begins at the end of the heat
demand by the heating controller.