Quiet Priority; Room Heater; Tank Heater; Sterilization - Panasonic WH-ADC0509L3E5 Operating Instructions Manual

Air-to-water hydromodule + tank
Hide thumbs Also See for WH-ADC0509L3E5:
Table of Contents

Advertisement

Menus
Menu

Quiet priority

1.4
• To select priority during Quiet
mode between Sound and
Capacity.
• If Sound priority is selected,
unit will operate in quiet
condition only.
• If Capacity priority is selected,
unit will operate in quiet
condition but it will prioritize on
providing required capacity at
the same time.

Room heater

1.5
To set the room heater ON or
OFF.

Tank heater

1.6
To set the tank heater ON or
OFF.

Sterilization

1.7
To set the auto sterilization ON
or OFF.
• Do not use the system during sterilization in order to prevent scalding with hot water, or overheating of shower.
• Ask an authorised dealer to determine the level of sterilization function fi eld settings according to the local laws and
regulations.
DHW mode (Domestic Hot Water)
1.8
To set the DHW mode to
Standard or Smart.
• Standard mode have faster
DHW Tank heat up time.
Meanwhile Smart mode
take longer time to heat up
DHW time with lower energy
consumption.
To set the tank sensor to Top
or Center.
• Selection of the tank sensor
to top slow down the start of
boiling up the tank and reduce
power consumption.
Please change this selection
to "Center" when the hot water
becomes insuffi cient.
28
For user
Default Setting
Sound
OFF
OFF
ON
Standard
Top
Setting Options / Display
Sound
Capacity