Advertisement

Quick Links

Air conditioner
Installation manual
AC***BNPDKH / AC***BXPD*H
• Thank you for purchasing this Samsung air conditioner.
• Before operating this unit, please read this installation manual carefully and retain it for future
reference.

Advertisement

Table of Contents
loading

Summary of Contents for Samsung AC BNPDKH Series

  • Page 1 Air conditioner Installation manual AC***BNPDKH / AC***BXPD*H • Thank you for purchasing this Samsung air conditioner. • Before operating this unit, please read this installation manual carefully and retain it for future reference.
  • Page 2: Table Of Contents

    Contents Safety Information Installation Procedure Step 1 Choosing the installation location Step 2 Unpacking Step 3 Checking and preparing accessories Step 4 Drilling a hole through a wall Step 5 Taping the pipes, cables, and drain hose Step 6 Connecting the refrigerant pipes Step 7 Optional: Cutting and flaring the pipes Step 8 Connecting the power and communication cables Step 9 Optional: Extending the power cable...
  • Page 3: Safety Information

    This manual explains how to install an indoor unit with concerning use of the appliance by a person a split system with two SAMSUNG units. The use of responsible for their safety. Children should be other types of units with different control systems may supervised to ensure that they do not play with the damage the units and invalidate the warranty.
  • Page 4 Safety Information Installing the unit • Always verify that electric connections (cable entry, section of leads, protections…) are compliant with the electric specifications and with the instructions provided in the wiring IMPORTANT: When installing the unit, always remember to scheme. Always verify that all connections comply with the connect first the refrigerant tubes, then the electrical lines.
  • Page 5 Operation Features Checking auxiliary power switch Turn on the auxiliary power switch which is installed separately. 1 phase circuit breaker 3 phase 4 wire circuit breaker NOTE Auxiliary power switch (ELCB, ELB) • Auxiliary power switch is not included in the package. Purchase and install it separately. •...
  • Page 6: Installation Procedure

    Installation Procedure Step 1 Choosing the installation • If there is any unavoidable reason to install the unit at such a place, take the following measures: location – When installing the unit at a roadside concentrated with Determine the installation location considering the following buildings, install it parallel to the road.
  • Page 7 1500 or more • If the product installed within 500m of seashore, special more more anti-corrosion treatment is required. Please contact your local SAMSUNG representative for 500 or further details. more 300 or Minimum clearances for the outdoor unit more...
  • Page 8 Installation Procedure – Make sure that there is no device that can generate WARNING electromagnetic waves. Otherwise, a malfunction of the control system may occur. For example, the • Should adopt bar type louver. Don’t use a type of rain indoor unit remote control sensor may not properly resistance louver.
  • Page 9: Step 2 Unpacking

    Step 2 Unpacking Accessories in the outdoor unit package Unpacking the indoor unit Drain cap (3) Drain plug out (1) Open the indoor unit package. Remove the top and middle cushions. Remove the bottom cushion. Rubber leg (4) Unpacking the outdoor unit Pull out the outdoor unit from the package.
  • Page 10: Step 6 Connecting The Refrigerant Pipes

    Installation Procedure Wind the refrigerant pipes, power cable, communication Indoor cable, and drain hose with vinyl tape to make a pipe bundle. Outdoor Pipe insulator Vinyl tape • Temper grade and minimum thickness of the Indoor/outdoor unit refrigerant pipe communication cable Drain hose Outer diameter [mm] Minimum thickness [mm]...
  • Page 11 Outdoor unit Make at least one round: It will reduce noise and vibration After connectiong the pipes, block the part . Liquid (A) Heat radiation holes Do not block the holes. • The appearance of the unit may be different from the diagram depending on the model.
  • Page 12: Step 7 Optional: Cutting And Flaring The Pipes

    Installation Procedure Step 7 Optional: Cutting and flaring Step 8 Connecting the power and the pipes communication cables Make sure that you have the required tools; pipe cutter, CAUTION reamer, flaring tool, and pipe holder. If you want to shorten the pipes, cut it with a pipe cutter, •...
  • Page 13 AC100BNPDKH (1-phase) Outdoor-to-indoor power and communication cables specifications V1/V2 Connector Indoor Unit Indoor power supply 1(L) 2(N) Power supply Max/Min (V) Indoor power cable ±10% Communication cable Communication DC 12V Cable clamp F1/F2 0.75 mm², 2 wires Wi-Fi Kit Connection NOTE Outdoor Unit •...
  • Page 14 Installation Procedure Connecting the cables Thickness of the wire (mm²) B (mm) d2 (mm) Less than 9.5 More than 4.5 AC100BXPDKH Less than 9.5 More than 4.5 Less than 9.5 More than 4.5 • This product uses a single phase power, with 220 to 10.0 Less than 15 More than 8.4...
  • Page 15 Indoor and outdoor unit connection diagram Entire system diagram Communication cable Indoor unit Outdoor-to-indoor power cable Electrical panel Earthing Outdoor unit Main power cable NFB 3phase 4 Ground wire wires, 380 to 1(L) 2(N) L 1(L) 2(N) F1 F1 415V, 50 Hz Outdoor unit Indoor unit Power wiring diagram...
  • Page 16: Step 9 Optional: Extending The Power Cable

    Installation Procedure Step 9 Optional: Extending the power NOTE cable Voltage range • Units are suitable for use on electrical systems Prepare the following tools. where voltage supplied to unit terminal is not below or above listed range limits Tools Spec Shape Maximum allowable voltage variation between phases...
  • Page 17 Insert both sides of core wire of the power cable into the Wrap it with the insulation tape twice or more and connection sleeve. position your contraction tube in the middle of the insulation tape. • Method 1: Push the core wire into the sleeve from both sides.
  • Page 18: Step 10 Checking The Earthing

    Installation Procedure Step 10 Checking the earthing Step 11 Performing gas leakage test If the power distribution circuit does not have a earthing or Use nitrogen gas at a pressure range between 0.2 and 4.1 MPa the earthing does not comply with specifications, an earthing when testing the gas leakage.
  • Page 19: Step 12 Evacuating The Air

    Step 12 Evacuating the air Connect the manifold gauge to a vacuum pump. Indoor unit Purge the air from the system using the vacuum pump for Outdoor unit about 30 minutes. • Make sure that pressure gauge shows -0.1006 Mpa after about 30 minutes.
  • Page 20 Installation Procedure Tightening torque Liquid side service valve Outer diameter (mm) Body cap (N•m) Charging port cap (N•m) Gas side service valve ø 6.35 20 to 25 Manifold gauge ø 9.52 20 to 25 High pressure side Indoor unit ø 12.70 25 to 30 10 to 12 Low pressure side...
  • Page 21: Step 14 Fixing And Insulating The Connection Part For Refrigerant Pipes

    Step 14 Fixing and insulating the Fasten the pipes with a pipe clamp and fix it with screws. connection part for refrigerant pipes CAUTION • Before wrapping the connection part for refrigerant pipes, be sure to check whether there is gas leakage on the connection part.
  • Page 22: Step 16 Performing Drainage Test

    Installation Procedure Insert the end of the drain hose to the extension drain Step 16 Performing drainage test hose to make a connection. Put the water bottle deeply into the first blade on the left of Tightly wrap the connection part with a cable tie or tape the air outlet and slowly pour water.
  • Page 23: Step 18 Performing The Final Check And Trial Operation

    Step 18 Performing the final check Outdoor unit and trial operation Check the power supply between the outdoor unit and the auxiliary circuit breaker. • 1 phase power supply: L, N • 3 phases power supply: R, S, T, N Check the indoor unit.
  • Page 24 Installation Procedure View mode: When the K4 switch is pressed, you can see information about our system state, as detailed below. K4 short push Display contents SEG1 SEG2 SEG3 SEG4 Unit Order frequency Hundreds digit Tens digit Units digit Current frequency Hundreds digit Tens digit Units digit...
  • Page 25 Setting outdoor unit option switch and address manually Input Option item SEG1 SEG2 SEG3 SEG4 Function unit Setting the option Temperature Celsius (default) Main • Press and hold K2 to enter the option setting. (Only Fahrenheit unit available when the operation is stopped) Not applicable Not applicable Main –...
  • Page 26 Installation Procedure Emergency Temperature Output (ETO) function CAUTION • In order to deploy the ETO function, the MIM-B14, an external contact interface module, must be installed in each indoor unit. – The ETO is a concept of emergency operation of indoor units. If the indoor unit 1 (main indoor unit) stops because of an error, the indoor unit 2 (sub indoor unit) starts to operate.
  • Page 27: Step 19 Pumping Down Refrigerant

    ETO operation specifications Main indoor unit – Based on the external contact control settings, the main indoor unit decides whether to generate output when an error (indoor unit stop) occurs. – Based on the ETO settings, the main indoor unit decides whether to generate output according to the temperature and time conditions.
  • Page 28: Appendix

    Appendix Appendix Troubleshooting The table below lists the self-diagnostic routines. For some of error codes, you must contact an authorized service centre. If an error occurs during the operation, it is displayed on the outdoor unit PCB LED, both MAIN PCB and INVERTER PCB. No.
  • Page 29 No. Error Code Meaning Remarks 1. Check if the service valve is open 2. Check the state of refrigerant E464 IPM Over Current(O.C) 3. Check if connecting wire and the pipe are OK 4. Check the compressor E465 Comp. Over load error E466 DC-Link voltage under/over error Check AC Power and DC Link Voltage...
  • Page 30: Commission Delegated Regulation (Eu) No 626/2011 Product Fiche (Energy Labelling Of Air Conditioners)

    Appendix COMMISSION DELEGATED REGULATION (EU) No 626/2011 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) Supplier's name Samsung Model name (Indoor/Outdoor) AC100BNPDKH/AC100BXPDKH Sound Power Level (Indoor/Outdoor) dB(A) 60 / 70 R-410A 2088 SEER Energy efficiency class (SEER) QCE2) (cooling season) kWh/a...
  • Page 31 [Spanish-ES] [French-FR] [Italian-IT] [Portuguese-PT] REGLAMENTO DELEGADO (UE) No RÈGLEMENT DÉLÉGUÉ (UE) No REGOLAMENTO DELEGATO (UE) N. REGULAMENTO DELEGADO (UE) N.o 626/2011 DE LA COMISIÓN 626/2011 DE LA COMMISSION 626/2011 DELLA COMMISSIONE 626/2011 DA COMISSÃO Ficha del producto (etiquetado Fiche produit (l'indication, par voie Scheda prodotto (l'etichettatura Ficha de produto (rotulagem energético de los acondicionadores...
  • Page 32 Appendix [German-DE] [Greek-EL] [Dutch-NL] [Polish-PL] DELEGIERTE VERORDNUNG (EU) Nr. GEDELEGEERDE VERORDENING (EU) 626/2011 DER KOMMISSION VAN DE COMMISSIE Nr. 626/2011 KOMISJI (UE) nr 626/2011 Produktdatenblatt (die Kennzeichnung Productkaart (energie-etikettering van von Luftkonditionierern in Bezug auf airconditioners) den Energieverbrauch) kWh/a kWh/a kWh/a Name des Lieferanten Naam van leverancier...
  • Page 33 [Hungarian-HU] [Czech-CS] [Slovak-SK] [Romanian-RO] A BIZOTTSÁG 626/2011/EU DELEGOVANÉ NARIADENIE KOMISIE REGULAMENT DELEGAT (UE) NR. FELHATALMAZÁSON ALAPULÓ 626/2011 AL COMISIEI RENDELETE klimatizátorov energetickými) energiafogyasztásának címkézése) vzduchu) kWh/év kWh/rok kWh/rok kWh/a Název dodavatele Nume furnizor Típus neve(beltéri/kültéri) Názov modelu(vnútorná/vonkajšia) Nume model(interior/exterior) Hladina akustického výkonu C Hangteljesítményszint (beltéri/kültéri) venkovní) (vnútorná/vonkajšia)
  • Page 34 Appendix [Bulgarian-BG] [Croatian-HR] [Slovenian-SL] [Danish-DA] DELEGIRANA UREDBA KOMISIJE (EU) DELEGIRANA UREDBA KOMISIJE (EU) KOMMISSIONENS DELEGEREDE br. 626/2011 št. 626/2011 FORORDNING (EU) Nr. 626/2011 Podatkovna kartica izdelka Informacijski list proizvoda Datablad (energimærkning af klimaanlæg) naprav) kWh/a kWh/a kWh/a kWh/a Ime dobavitelja Leverandørs navn Naziv modela (u zatvorenom/ Ime modela (notranja/zunanja)
  • Page 35 [Swedish-SV] [Finnish-FI] [Estonian-ET] [Latvian-LV] KOMMISSIONENS DELEGERADE DELEGOITU KOMISSION ASETUS (EU) KOMISJONI DELEGEERITUD MÄÄRUS FÖRORDNING (EU) nr 626/2011 N:o 626/2011, (EL) nr 626/2011, Nr. 626/2011 Produktblad (energimärkning av Tuoteseloste (huoneilmastointilaitteiden Tootekirjeldus (kliimaseadmete luftkonditioneringsapparater) energiamerkinnän osalta) energiamärgistusega) kWh/a kWh/v kWh/a kWh/a Toimittajan nimi Tarnija nimi Modellnamn (inomhus/utomhus) Mallinimi (sisällä/ulkona)
  • Page 36 Appendix [Lithuanian-LT] [Serbian-SR] KOMISIJOS DELEGUOTASIS REGLAMENTAS (ES) Nr. 626/2011 kWh/a kWh/godišnje Naziv modela (unutršnja jedinica/ Modelis pavadinimas (patalpoje / lauke) spoljašnja jedinica) Nivo buke (unutrašnja/spoljna Garso galios lygis (patalpoje / lauke) jedinica) SEER SEER Klasa energetske efikasnosti (SEER) Pdesignc Pdesignc SCOP SCOP Klasa energetske efikasnosti (SCOP)
  • Page 37 [Spanish-ES] Las fugas de refrigerante contribuyen al cambio climático. Cuanto mayor sea el potencial de calentamiento global (GWP) intente intervenir en el circuito del refrigerante ni desmontar el aparato usted mismo; consulte siempre a un profesional. Consumo de energía “XYZ” kWh/año, según los resultados obtenidos en ensayos estándar. El consumo de energía real depende de las condiciones de uso del aparato y del lugar en el que esté...
  • Page 38 Appendix [Portuguese-PT] aquecimento global (PAG) contribuem menos para o aquecimento global do que os fluidos refrigerantes com maior PAG, em caso de fuga para a atmosfera. Este aparelho contém um fluido refrigerante com um PAG igual a [xxx]. Isto significa que, se ocorrer uma fuga de 1 kg deste fluido refrigerante para a atmosfera, o seu impacto no aquecimento global será...
  • Page 39 [Dutch-NL] Lekkage van koelmiddel leidt tot klimaatverandering. Bij lekkage in de lucht draagt een koelmiddel met een laag aardopwarmingsvermogen (GWP) minder bij tot de opwarming van de aarde dan een koelmiddel met een hoog GWP. Dit apparaat bevat een koelmiddel met een GWP gelijk aan [xxx]. Dit houdt in dat als 1 kg van deze koelvloeistof in de lucht vrijkomt, het effect op de aardopwarming over een periode van 100 jaar [xxx] keer groter zou zijn dan bij het vrijkomen van vakman.
  • Page 40 Appendix [Czech-CS] odborníka. [Slovak-SK] [Romanian-RO] 40 English...
  • Page 41 [Bulgarian-BG] [Croatian-HR] 100 godina. Nikada sami ne pokušavajte raditi bilo kakve zahvate na rashladnom krugu niti rastavljati proizvod i za to uvijek zovite profesionalca. [Slovenian-SL] potencialom globalnega segrevanja (GWP) k globalnemu segrevanju prispevalo manj kot hladilno sredstvo z višjim GWP. Ta hladilnega obtoka ali razstaviti naprave in za to vedno prosite strokovnjaka.
  • Page 42 Appendix [Swedish-SV] beror på hur apparaten används och var den placeras. beror på hur apparaten används och var den placeras. [Finnish-FI] Kylmäainevuodot vaikuttavat ilmastonmuutokseen. Kylmäaineen, jolla on alhaisempi ilmakehän lämmitysvaikutuspotentiaali (GWP), ilmastonmuutosvaikutus olisi pienempi kuin korkeamman GWP-arvon kylmäaineen, jos kylmäainetta pääsisi ilmakehään. Tämä laite sisältää kylmäainetta, jonka GWP-arvo on [xxx]. Tämä tarkoittaa, että jos yksi kilo tätä...
  • Page 43 [Lithuanian-LT] energijos kiekis priklauso nuo to, kaip prietaisas naudojamas ir kur jis pastatytas. energijos kiekis priklauso nuo to, kaip prietaisas naudojamas ir kur jis pastatytas. [Serbian-SR] Potrošnja energije „XYZ“ kWh godišnje, na osnovu rezultata standardnog testa. Stvarna potrošnja energije zavisi od toga kako Potrošnja energije „XYZ“...