7 7 . . 6 6 . . 9 9 C C h h e e c c k k T T h h e e T T e e m m p p e e r r a a t t u u r r e e R R e e g g u u l l a a t t i i o o n n
Check the temperature regulation of the internal cooling system.
N N o o t t e e
The temperature should stay at 2 2 5 5 ° ° C C ± ± 1 1 0 0 % % . . . Temperatures between 5 to 10 °C can be used,
but may cause severe condensation inside the machine.
1. Press M M e e n n u u .
2. Press S S e e r r v v i i c c e e P P a a g g e e .
3. Press H H a a r r d d w w a a r r e e S S t t a a t t u u s s .
4. Check that the indicator I I n n t t e e r r n n a a l l c c i i r r c c u u i i t t t t e e m m p p
shows 25 °C (± 10 %).
5. Check that the indicator I I n n c c o o m m i i n n g g c c o o o o l l i i n n g g w w a a t t e e r r
t t e e m m p p shows 10 to 20 °C.
6. Monitor the value for a period of time or use LogStu-
dio (Press Overview) to verify whether the tempera-
ture is being regulated correctly.