3 Operation Triplets
3.5.5 DG_CONTROL/DAT_EJECTCTL/MSG_SET
Format:
DS_Entry(pOrigin,pDest,DG_CONTROL,DAT_EJECTCTL,MSG_SET,
pEjectCtl);
pEjectCtl:pTW_EJECTCTL
3
typedef struct{
TW_UINT16 EjectInstruct; //Ejection indication flag
}TW_EJECTCTL, FAR * pTW_EJECTCTL;
Enabled status:
From 6 to 7
Explanation:
Specifies the sheet ejection indication. According to this specification, the source makes ejection
to a normal or abnormal stacker.
For ejection to a normal stacker, specify 0 in the ejection instruction flag.
For ejection to an abnormal stacker, specify 1 in the ejection instruction flag.
Once a sheet is ejected, the content of this specification is deleted and the source will determine
the ejection instruction.
Notes on the application
The source ejects a sheet being scanned while receiving
DG_CONTROL/DAT_PENDINGXFERS/MSG_ENDXFER.
The application must perform this specification before issuing
DG_CONTROL/DAT_PENDINGXFERS/MSG_ENDXFER.
This can be specified only when DG_CONTROL/DAT_DIVSCANCTL/MSG_SET is used to
specify the division of scan and ejection for execution.
Return code
TWRC_SUCCESS
Success
TWRC_FAILURE
TWCC_BADVALUE When the ejection instruction flag is other than 0 and 1
TWCC_SEQERROR Invalid sequence