3 Operation Triplets
3.5.7 DG_CONTROL/DAT_EJECTNUMBERING/MSG_GET
Format:
DS_Entry(pOrigin,pDest,DG_CONTROL,DAT_EJECTNUMBERING,MSG_GET,
pNumberingCnt);
pNumberingCnt:pTW_UINT16
3
Enabled status:
From 6 to 7
Explanation:
For numbering at the ejection of a sheet, you can acquire the maximum value for the specifiable
number of numbering print characters. When you specify numbering characters at the ejection of
a sheet, they must be not greater than the number of numbering print characters entered by this
specification.
The number of numbering print characters is returned to pNumberingCnt.
Notes on the application
The number of numbering characters returned by this content is the number of numbering print
characters in the UI-specified numbering settings.
Return code
TWRC_SUCCESS
Success
TWRC_FAILURE
TWCC_SEQERROR Invalid sequence
Limitations:
This operation is supported only by the front side numbering.
When the back side numbering is set, this operation returns a value of 0 as the number of
characters.
3-13