Vertical Fl Uing Options; Accessories - Bosch WORCESTER Greenstar CDi Classic Series Technical Information

Gas-fired condensing wall mounted boiler range
Table of Contents

Advertisement

Greenstar combi boiler range
vertical fl uing options
The Greenstar combi boiler range offers the choice of
2 differently sized vertical RSF fl ue systems, 100mm and
125mm. Both systems have different maximum lengths.
The following diagrams detail the permissible lengths.
Vertical RSF fl ue
Flue diameter
Greenstar CDi Classic series
Minimum fl ue length
Maximum fl ue length
(inc. adaptor)
29CDi Classic
34CDi Classic
38CDi Classic
42CDi Classic
Greenstar CDi Compact and Si Compact series
Minimum fl ue length
Maximum fl ue length
(inc. adaptor)
Greenstar i Junior series
Minimum fl ue length
Maximum fl ue length
(inc. adaptor)
100mm dia. vertical balanced fl ue kit
1 x fl ue terminal assembly
1 x weather sealing collar
1 x fi re stop spacer
1 x vertical adaptor
Part No. 7 719 002 430
125mm dia. vertical balanced fl ue kit
1 x fl ue terminal assembly
1 x weather sealing collar
1 x fi re stop spacer
1 x vertical adaptor
Part No. 7 719 002 431
48
48
100mm
125mm
1,090mm
1,365mm
9,400mm
18,500mm
8,000mm
16,000mm
7,500mm
16,000mm
7,500mm
16,000mm
1,090mm
1,365mm
6,000mm
15,000mm
1,090mm
1,365mm
6,400mm
15,000mm

Accessories

Components
Part No.
100mm diameter
7 719 002 430
7 716 191 083 Extension fl ue kit (960mm*)
7 716 191 172 2m fl ue extension
7 716 191 133 Short fl ue extension (220mm*)
7 716 191 084 90º bend
7 716 191 085 45º bend
7 716 191 090 Flashing – fl at roof
7 716 191 091 Flashing – pitched roof
*Dimensions when fi tted
125mm diameter
7 719 002 431
7 719 003 666 Extension fl ue kit (960mm*)
7 719 003 664 90º bend
7 719 003 665 45º bend
7 716 191 090 Flashing – fl at roof
7 716 191 091 Flashing – pitched roof
*Dimensions when fi tted
The following criteria should be noted when planning
the installation:
Because the appliance operates at high effi ciency, a
white plume of condensation will be emitted from the
terminal. Care must be taken when selecting the fl ue
terminal position
To achieve a maximum fl ue length, one of the extension
fl ue kits will need to be cut so that the permitted
maximum fl ue length is not exceeded
Vertical fl ue options 1-4 illustrate common fl ue
installations. Other confi gurations of the fl ue system are
possible up to, and not exceeding, the stated maximum
fl ue lengths.
Description
Vertical 1,090mm balanced
fl ue kit (inc. adaptor)
Vertical 1,365mm balanced
fl ue kit (inc. adaptor)