Download Print this page

Bosch CM368B Installer's Reference Manual page 3

Ip combo module - 4g lte cat 1

Advertisement

base station in Conettix IP, SIA IP, CSV or to selected phone
numbers via SMS.
All reporting scenarios are configured by varying the pro-
gramming of the reporting format and reporting routes
configurations options.
Module Indicators
The module includes a total of 12 led indicators which
are used to show status and signal strength information.
Separate indicators are provided for the GSM and Ether-
net systems. Additional feedback is provided through the
keypad and via the interactive option in Solution Link.
See the tables below.
Module Indicators
Indicator
TX
Module Transmitting Data
RX
Module Receiving Data
ON Steady = Not Registered On Network
Online
Pulsing = Registered On Network
Signal 1
Signal strength indicators show relative
Signal 2
signal level at the radio. Signal indicator 1
on indicates weak signal and all 4 indicators
Signal 3
on indicates stronger signal strength.
Signal 4
Table 2: GSM/GPRS Indicator Meanings
Ethernet Indicators
Indicator
TX
Transmitting Data via Ethernet
RX
Receiving Data via Ethernet
ON = Trouble - No Communication
between Panel and Module.
STATUS
Slow Flash = Normal Operation
Fast Flash = No IP Address or IP Address
Conflict - See System Troubles
Flashes every time the control panel sends
POLL
a poll packet.
Flashes each time the control panel sends
REPORT
an alarm report.
Table 3: Ethernet Indicator Meanings
RJ45 Socket Indicators
Green LED
OFF
No Link / Connection
ON
Link Present
Blinking
Link with TX / RX Activity
Amber LED
OFF
Half Duplex Activity
ON
Full Duplex Activity / Off
Blinking
Collision Activity
Table 4: RJ45 Socket Indicator Meanings
Bosch Security Systems
03/21 CM368BIRG FTR1.0
Meaning
Meaning
Meaning
Meaning
Supported Reporting Formats
Version 2.51.04 of the Solution 6000 panel firmware is
required to support the CM368B.
The following reporting formats are currently supported
by the module.
SMS Format via GSM
CSV-IP Format via GPRS
Conettix Format via GPRS
CSV-IP Format via Ethernet
Conettix Format via Ethernet
There is no support for Contact ID (CID) over GSM.
CLI Trigger Output Control
The CLI trigger tables in MENU 6-5-5-0 and 6-5-6-1 can be
used to store a list of telephone numbers that can trigger
an output on the control panel. If you call the GSM unit
from a telephone number that matches a number in the
CLI list then the appropriate output will be operated.
An output needs to be programmed with an event type of
CLI Trigger and event assignment of 1 or 2 depending on
which table is to be checked.
Simply call the GSM unit from a telephone number that is
programmed in the CLI trigger list to activate the output.
Module Status
MENU 6-5-0 can be used to obtain various information on
the radio module. The following information is currently
available.
1) Connected Network
2) Signal Strength in dB
3) IMEI Number
4) Radio Firmware Revision
5) SIM Card Present
CM368B