Figure 9: MAC Address Selection
Go to the Ethernet Module section in the Devices tab and
uncheck the "Obtain IP Address Automatically" option
then enter the IP Address of the CM368B, the Subnet Mask
and the Default Gateway in the fields provided and then
save the changes.
Figure 10: Subnet Mask and Default Gateway Entry
Step 3 - Configuring the Panel for IP Reporting
Before you will be able to configure the panel for IP
reporting you will need to make sure you have the rel-
evant information from the control room. The following is
required,
1.
IP Address for the base station's IP Receiver.
2.
IP Port for the base station's IP Receiver.
3.
Poll Rate.
4.
Acknowledge Wait Time.
5.
Reporting Format.
6.
If Conettix NNC Anti Replay format is being used,
you will need the base station allocated NNC
Number.
7.
If encryption is required you will need the base
station allocated Encryption Key.
Bosch Security Systems
03/21 CM368BIRG FTR1.0
Move to the Reporting Route section on the Comms tab
and set the transmission format to Ethernet format for
Destination 1, 2 or both as required.
Figure 11: Configuring the Transmission Format
Move to the IP Reporting section on the Comms tab and
enter the Base Station Receiver IP Address, IP Port and
other parameters as supplied by the control room. Enter
the details in the appropriate destination as required.
Figure 12: Configuring the Base Station's IP Settings
If you are using the Conettix NNC anti replay feature or
data encryption move to the Ethernet Module section on
the Devices tab and enter respective information. The
values entered here must match those in the base station
or communication will fail.
To remove encryption set the key back to all zeros or the
factory default settings.
CM368B
Installer Reference Guide
9