Interfaces; Overview - Siemens MCP 398C Manual

Machine control panel
Table of Contents

Advertisement

Note
No built-in elements are equipped in the delivery state.
2.3

Interfaces

2.3.1

Overview

Interface
X10
X20
X21
X30
X31
X32
X51 /
X52 / X55
X53 / X54 Interfaces for customer-specific outputs
X60 / X61 Connections for two handwheels (TTL / differen‐
The following special requirements apply for the connection cables:
● The 24 VDC cable must be approved for temperatures up to 70° C.
● Select the permitted conductor cross-section in accordance with the national regulations
(NEC, VDE, etc.) and the "Power supply connectors for MCP 398C" table below. The line
protection in accordance with the national regulations (NEC, VDE,...) must be guarantied
as appropriate for the selected conductor cross-section.
● Strip the cables (7 mm) for connection to the 24 VDC connector.
● Flame resistance of the 24 VDC cable in accordance with UL 2556 VW-1 / or tested in
accordance with IEC 60332-1-2.
● Observe the permissible bending radius of the cables.
Machine control panel: MCP 398C
Manual, 12/2017, A5E43199783B AA
Designation
24 V power supply interface
Ethernet 1
Ethernet 2
Interface for feedrate override rotary switch
Interface for spindle override rotary switch
Interface for additional override switch
Interfaces for customer-specific inputs
tial - can be set with switch S1)
Protective conductor connection
2.3 Interfaces
Max. cable length: Type
10 m
Terminal block, 3-
pin
100 m
RJ45
100 m
RJ45
0.6 m
10-pin male con‐
nector
0.6 m
10-pin male con‐
nector
0.6 m
10-pin male con‐
nector
0.6 m
4-pin male connec‐
tor
0.6 m
4-pin male connec‐
tor
5 m
15-pin Sub-D male
connector
Length and cross
M5 screw
section in accord‐
ance with the na‐
tional regulations
Description
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d sl

Table of Contents