Chapter 2
Installing the Subscriber Unit
Figure 15: Untwisting the Wire Pairs
6.
Arrange the wires according to the following pin-out description:
Figure 16: CAT-5e PoE Cable Pin-Out
1. Pin 1    2. Pin 8
7.
Slide the wires into the loading bar and then pull the loading bar down until its face is 16 mm (0.63 in) from
the wire jacket. If necessary, use pliers to hold the wires while pulling the loading bar.
1
Figure 17: 
1. Loading Bar    2. Wires    3. Pin 1    4. Pin 8
8.
Trim the wires until they are flush with the face of the loading bar.
9.
Insert the wires and loading bar into the plug body. Make sure:
• the cable is pushed to the front of the plug body
• the spine of the strain relief on the plug body covers the drain wire
10. Bend the strain relief until it is flat against the jacket and foil.
11. Crimp the plug and strain relief using a standard crimping tool.
22
2
1
8
6 7
4 5
2 3
1
2
Pin
Color
Number
1
White/Orange
2
Orange
3
White/Green
4
Blue
5
White/Blue
6
Green
7
White/Brown
8
Brown
2
1
1
2
3
RUGGEDCOM WIN5118
Installation Guide
Description
ETH Data
ETH Data
ETH Data
48 V
48 V
ETH Data
RTN (-)
RTN (-)
1
7
5
8
3
6
4
4
Assembling the PoE Connector
TP0+
TP0-
TP1+
TP2+
TP2-
TP1-
TP3+
TP3-