Installation Of The Pc In The Control Cabinet; Earthing Measures - ABB Control Cabinet PC C6240 Installation And Operating Instructions Manual

Table of Contents

Advertisement

Installation Instructions
Preparation of the control
cabinet
i
Note
Warning

Earthing measures

10

Installation of the PC in the control cabinet

The C6240 Industrial PC is designed for mounting in control cabinets for
machine and plant engineering applications.
The ambient conditions specified for operation must be observed (see
chapter
Technical
data).
Four holes for the fixing bolts have to be provided in the control cabinet
according to the dimensions of the PC (see chapter
When the unit is installed in an enclosure, adequate space for
ventilation and for opening the PC must be provided.
The clearance above and below the housing must be at least 50 mm
in order to ensure adequate ventilation of the PC.
Extreme environmental conditions should be avoided as far as
possible. Protect the PC from dust, moisture and heat.
The ventilation slots of the PC must not be covered.
Earthing measures
Earthing connections dissipate interference from external power supply
cables, signal cables or cables to peripheral equipment.
.
Establish a low-impedance connection from the earthing point on the PC
housing to the central earthing point on the control cabinet wall, in which
the computer is being installed. The earthing connection is located at the
bottom side of the housing (see photograph on the left).
Assembly
dimensions).
C6240

Advertisement

Table of Contents
loading

This manual is also suitable for:

Control cabinet pc c0060

Table of Contents