Initialization (Reset)/Functional Restriction Setting

You can return the settings to their factory-preset values and
restrict operations.
1. After pressing
for about 5 seconds, press
, and
in that order.
FUNCTION 1
ALL RESET
ADJUSTMENT LOCK
OFF
OSD DISPLAY
OFF
LED
OFF
TEMP ALERT
OFF
RS-232C
LOCKED
2. Select and set the items.
ALL RESET
Resets the settings to the factory default settings.
After initialization, turn the main power switch off and
then back on.
ADJUSTMENT LOCK
You can disable operations on the monitor and the
remote control unit that use buttons.
OFF ...Enables operation.
1.........Disables all operations other than turning power
on/off and FUNCTION 1.
2.........Only the FUNCTION 1 operation is enabled.
Disables all operations other than FUNCTION 1
(not even power on/off).
OSD DISPLAY
Hides/shows menus.
The FUNCTION 1 screen cannot be hidden.
LED
Specifies whether to light power LED.
TEMP ALERT
Selects the notification method for an abnormal
temperature.
OFF .............. Do not notify about an abnormal
temperature.
OSD&LED .... When an abnormal temperature is
detected, the power LED flashes in red
and green alternately and the screen
displays a message: TEMPERATURE.
LED............... When an abnormal temperature is
detected, the power LED flashes in red
and green alternately.
RS-232C
Specifies whether to allow control via RS-232C (see
page 12).
LOCKED ....... Disables control via RS-232C.
UNLOCKED.. Enables control via RS-232C.
3. Press
to return to the normal screen.
,
,
ALL RESET
1
2
ON
ON
LED
OSD&LED
UNLOCKED
OK...[MENU]
11