5

9.3.12 QSI (INPUT SIGNAL DATA)

The command QSI is for acquiring all data on input video signals.
Command
Effective Operation
Format
Modes
[QSI]
All operations
Data Arrangement
ECO
1
Type of drive sequence
2
Standard/nonstandard
3
Type of ABL/WB tables
4
Total value of PCN
5
Total value of PRH
6
Total value of PGH
7
Total value of PBH
8
Total value of PBR
9
Total value of PRL
10
Total value of PGL
11
Total value of PBL
12
Total value of ABL
13
V frequency distinction
14
Reserved
15
Reserved
16
APL acquiring data
17
Number of SUS pulses
18
Result of detection of still picture
19
Result of detection of cracking in the panel
20
Result of detection for scanning protection
21
Result of detection for external protection
22
Transition of protection operation
23
Reserved
24
CS

9.3.13 DRV (PANEL DRIVE-POWER ON / OFF)

Drive ON/OFF: ON/OFF control of panel drive-power system
Command
Effective Operation
Format
Modes
[DRV+S00]
Every time
[DRV+S01]
Every time
Once the DRIVE OFF command is accepted, DRIVE OFF cannot be canceled by pressing the DRIVE OFF key again or by
turning the unit off then back on with the STANDBY OFF/ON key.
To cancel DRIVE OFF, restart the unit by unplugging then again plugging in the power cord.
5
6
Function
To acquire all data on input video signals
Output
Data
Example
Length
3 Byte
QSI (fixed)
3 Byte
60V
1 Byte
S
2 Byte
T1
4 Byte
0256
4 Byte
0256
4 Byte
0256
4 Byte
0256
4 Byte
0512
4 Byte
0512
4 Byte
0512
4 Byte
0512
3 Byte
128
4 Byte
6002
1 Byte
∗∗∗∗
4 Byte
4 Byte
1023
4 Byte
0457
1 Byte
1
1 Byte
1
1 Byte
1
1 Byte
1
1 Byte
1
∗∗∗∗
4 Byte
2 Byte
27
Function
DRIVE OFF
DRIVE ON (default)
PDP-5010FD
6
7
Remarks
Return data: 3 (ECO) + 66 (DATA) + 2 (CS) = 71 Byte
1: Type of Drive
3: Type of ABL/WB
sequence
Tn
50V Video 50 Hz
60V Video 60 Hz
13: V frequency
72V Video 72 Hz
75V Video 75 Hz
Reading value *100
60P PC 60 Hz
16: APL acquiring
70P PC 70 Hz
2: Standard/
Output with 10 bit 0 to 1023
nonstandard
S
Standard
17: Number of SUS
N
Nonstandard
0174 to 2752
18 to 21: Each protection function
0
Setting: OFF
1
Setting: ON (during wait)
2
Setting: ON (during operation)
22: Transition of protection
operations
0
Upper limit state for brightness
1
Brightness being reduced
2
Lower limit state for brightness
3
Brightness being increased
Remarks
7
8
A
tables
n: 1 to 4
distinction
B
data
pulses
C