Descriptions For Setting Items; Setting Of Motion Sensor - Hitachi RPC-5.0FSR Operation Manual

Inverter-driven multi-split system heat pump air conditioners, ceiling
Table of Contents

Advertisement

9.3 Descriptions for Setting Items
● Motion Sensor Setting
The operation mode for activations for function
can be selected as follows:
* ALL MODES:
Function is available when the operation mode
is "COOL", "DRY", "HEAT" or "FAN".
* COOL+DRY:
Function is available when the operation mode
is "COOL", "DRY" or "FAN".
* HEAT:
Function is available when the operation mode
is "HEAT".
* OFF:
Functions is not available.
(The default setting is "ALL MODES".)
● If absent
"If absent" is set for the indoor unit operation
after the motion sensor detects as absence for
set time in "Check interval". The operation can
be selected from "ON", "Stand-by" or "OFF" on
the wired controller.
(The default setting is "ON".)
* ON:
The operation is continued with saving the
capacity after detected as an absence.
If the human activity is detected for a period of
time, the normal operation will be performed
again.
* Stand-by:
The operation mode is the fan operation at
"Slow" speed. If the human activity is detected
for a period of time, the normal operation will
be performed again.
* OFF:
The operation is stopped by the wired
controller when all the indoor units with motion
sensor detect absence which are connected
with same wired controller.
If the human activity is detected for a period of
time by the stoppage, the normal operation is
performed again.
● Check Interval
When the motion sensor detects an absence
at selected check interval time, the function "If
absent" will be executed. The interval can be
selected from 30, 60, 90 120 or 180 minutes.
(The default setting is 30 minutes.)
A10762290A
9.4 Setting of Motion Sensor
(1) Press "Menu".
Select "Motion Sensor Setting" from the
menu by pressing " " or " " and press "OK".
Menu
OK
Back/Help
Menu
OK
Back/Help
(2) "Motion Sensor Setting" is displayed.
The highlighted item is shifted to "Sensor",
"If absent" and "Check interval" by pressing
" " or " ".
Menu
OK
Back/Help
• To set "Sensor", move to procedure (3).
• To set "If absent", move to procedure (5).
• To set "Check interval", move to procedure (7).
(3) Press " " or " " and select "Sensor".
Menu
OK
Back/Help
(4) The display is switched "ALL MODES",
"COOL+DRY", "HEAT" and "OFF" in order by
pressing " " or " " and change the setting.
If other settings are not required, move to
procedure (9).
Menu
OK
Back/Help
15:10(Fri)
Menu
Individual Louver Setting
Louver Open/Close
03
VENTI
/
Total Heat Exchanger SET
05
Motion Sensor Setting
Sel.
OK
Entr
Back
Rtrn
Motion Sensor Setting
Sensor
ALL MODES
If absent
ON
Check interval
30min
Sel.
Adj.
OK
Entr
Back
Rtrn
Motion Sensor Setting
Sensor
ALL MODES
If absent
ON
Check interval
30min
Sel.
Adj.
Entr
Rtrn
OK
Back
Motion Sensor Setting
Sensor
ALL MODES
If absent
ON
Check interval
30min
Sel.
Adj.
Entr
Rtrn
OK
Back
11