Download Print this page
Sealey IR20.V4 Manual

Sealey IR20.V4 Manual

Infrared paraffin / kerosene / diesel heater

Advertisement

Quick Links

thank you for purchasing a sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear protective
instructions
gloves
this product is not suitable for primary heating purposes.
1. safety
1.1.
eleCtriCal safety
WarninG! It is the user's responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and
all electrical connections for wear and damage. Sealey recommend that an RCd (Residual Current device) is used with all electrical
products. You may obtain an RCd by contacting your local Sealey stockist.
If used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable Appliance Test) tested.
electrical safety information, it is important that the following information is read and understood.
ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
9
Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
9
Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the correct fuse - see
9
fuse rating in these instructions.
do not pull or carry the appliance by the power cable.
8
do not pull the plug from the socket by the cable.
8
do not use worn or damaged cables, plugs or connectors. ensure that any faulty item is repaired or replaced immediately by a
8
qualified electrician.
This product is fitted with a BS1363/A 13 Amp 3 pin plug.
9
If the cable or plug is damaged during use, switch the electricity supply and remove from use.
Ensure that repairs are carried out by a qualified electrician.
Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualified electrician.
1.2.
General safety
danGer! Risk of carbon monoxide poisoning. Failure to provide proper ventilation could result in
serious illness or death.
Check that the heater is in sound condition and good working order. Take immediate action to repair
9
or replace damaged parts.
Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
9
Only use paraffin, diesel or kerosene to fuel this heater, in accordance with instructions contained in this manual.
9
locate heater on a level and stable surface.
9
WarninG! only use heater in well ventilated areas. ensure continuous ventilation is provided to the heater operating area via
windows and doors etc. If people are not required to be present in the heated area, the volume of air to be heated (m³)/heat output
(kW) ratio must be at least 10:1 and people must be advised not to remain in the heated area for prolonged periods. If people
are required to be present in the heated area, the volume of air to be heated (m³)/heat output (kW) ratio must be at least 30:1.
Ventilation must be to the outside of the premises in which the heater is to be operated. The total open area (m²) must be at least
0.003 times the total heat output (kW). The volume concentration of oxygen (o
WarninG! do not use the heater near flammable material, liquids, solids, gases or compressed gas cylinders etc.
do not stand or place any object less than 3m from the heater output and keep the heater a minimum of 2m from any walls or
8
objects.
do not use the heater in closed rooms, living areas, basements or below ground level.
8
do not allow untrained persons to operate the heater and do not operate the heater without the safety guard.
8
do not move or handle the heater when hot, without wearing protective gloves. never move the heater whilst it is operating.
8
do not leave the heater unattended for prolonged periods of time when in use. Switch the heater off and unplug from the mains
8
before leaving work area.
do not fill the fuel tank whilst the heater is running or still hot. do not over-fill the fuel container. Wipe up any spilt fuel
8
immediately.
© Jack Sealey limited
infrared paraffin / kerosene / diesel
heater
model no:
electrical
Hot surfaces
shock
hazard
Original Language Version
ir20.V4
Keep in dry area
do not cover
protect from rain
) in the heated room, must always remain above 17%.
2
Recommended fuse rating
3 Amp
IR20.V4 Issue 5 (ERP) 18/09/19

Advertisement

loading

Summary of Contents for Sealey IR20.V4

  • Page 1 Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: Specification

    4. asseMbly 4.1. Unpack the heater and check contents. Should there be any damaged or missing parts contact your Sealey stockist immediately. 4.2. Attach handle by lining up the holes in the handle with the holes in the upper shell of the heater (fig.1).
  • Page 3: Operation

    The fan blades should be cleaned at least once per heating season, depending on conditions. remove all accumulated dust and dirt with a burst of condensed air fig.5. fig.5 Original Language Version IR20.V4 Issue 5 (ERP) 18/09/19 © Jack Sealey limited...
  • Page 4: Troubleshooting

    6. Inspect all electrical connections. Transformer and Circuit Board. 7. Transformer Wires not connected to Spark 7. Re-attach Transformer wires to Spark Plug. Plug. 8. Defective Transformer. 8. Replace Transformer. Original Language Version © Jack Sealey limited IR20.V4 Issue 5 (ERP) 18/09/19...
  • Page 5 (if applicable) into approved containers and dispose of the product and fluids according to local regulations. sealey Group, kempson Way, suffolk business park, bury st edmunds, suffolk. ip32 7ar 01284 757500 01284 703534 sales@sealey.co.uk...
  • Page 6 The seasonal space heating energy efficiency ƞ ƞ 88.9 88.9 Energy efficiency classes Contact details: Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk, IP32 7AR. www.sealey.co.uk ERP Table 1 Original Language Version IR20.V4 Issue 5 (ERP) 18/09/19 © Jack Sealey limited...

This manual is also suitable for: