Download Print this page

Sealey IR37.V5 Manual

125,000btu/hr infrared space warmer paraffin/kerosene/diesel heater with wheels

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear
Instruction
Protective gloves
Manual
(refuelling)
THIS HEATER IS NOT SUITABLE FOR USE AS A PRIMARY HEATING SOURCE
1. SAFETY
1.1.
ELECTRICAL SAFETY
WARNING! It is the user's responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and
all electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical
products.
If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable
Appliance Test) tested.
Electrical safety information, it is important that the following information is read and understood.
Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power
supply.
Regularly inspect power supply cables and plugs for wear or damage and check all connections to
ensure that they are secure.
Important: Ensure that the voltage rating on the appliance suits the power supply to be used and that
the plug is fitted with the correct fuse - see fuse rating in these instructions.
DO NOT pull or carry the appliance by the power cable.
8
DO NOT pull the plug from the socket by the cable.
8
DO NOT use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or
8
is replaced immediately by a qualified electrician.
This product is fitted with a BS1363/A 3 pin plug.
If the cable or plug is damaged during use, switch off the electricity supply and remove from use.
Ensure that repairs are carried out by a qualified electrician.
Replace a damaged plug with a BS1363/A 3 pin plug. If in doubt contact a qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualified electrician.
1.1.1.
If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance
plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that the
capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use
of 2.5mm² section cable.
1.2.
GENERAL SAFETY
DANGER! Risk of carbon monoxide poisoning. Failure to provide proper ventilation could result in serious illness or death.
Check that the heater is in sound condition and good working order. Take immediate action to repair or replace damaged parts.
9
Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
9
Only use clean paraffin, diesel (NOT BIO-DIESEL) or kerosene to fuel this heater, in accordance with instructions contained in this
9
manual.
Locate heater on a level and stable surface.
9
Switch off if any irregularities occur.
9
WARNING! Only use heater in well ventilated areas. Ensure continuous ventilation is provided to the heater operating area via
windows and doors etc. If people are not required to be present in the heated area, the volume of air to be heated (mtr³)/
heat output (kW) ratio must be at least 10:1 and people must be advised not to remain in the heated area for prolonged periods. If
people are required to be present in the heated area, the volume of air to be heated (mtr³)/heat output (kW) ratio must be
at least 30:1. Ventilation must be to the outside of the premises in which the heater is to be operated. The total open area
(mtr²) must be at least 0.003 times the total heat output (kW). The volume concentration of oxygen (O²) in the heated room,
must always remain above 17%.
WARNING! DO NOT use the heater near flammable material, liquids, solids, gases or compressed gas cylinders etc.
DO NOT switch the heater off by disconnecting it from the mains. ALWAYS set the switch on the burner to the 'OFF' position and
8
allow the cooling cycle to finish, before disconnecting from the mains.
© Jack Sealey Limited
125,000BTU/HR INFRARED SPACE WARMER®
PARAFFIN/KEROSENE/DIESEL HEATER WITH
WHEELS
IR37.V5
MODEL NO:
Warning!:
DO NOT use
Hot surface
petrol
Original Language Version
Always unplug
Use heater in well
heater before
ventilated areas
servicing and
checking
Never use heater
where highly
flammable vapours
are present
RECOMMENDED
FUSE RATING: 3A
IR37.V5 Issue 2 (H,2) 20/04/23

Advertisement

loading

Summary of Contents for Sealey IR37.V5

  • Page 1 IR37.V5 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 The photocell is sensitive to sunlight, ignite in the shade. Listen for fan followed by pump, after switch position " " Priming essential when new, see 5.3.4. Radiant Observe the fuel level in the filter bowl. visor screws Clean fuel requires clean reservoir and clean transfer cans. Fig.1A © Jack Sealey Limited IR37.V5 Issue 2 (H,2) 20/04/23 Original Language Version...
  • Page 3 NOTE: If air has entered the fuel line; possible when new, when left standing for a long period or when the tank level has fallen too low, priming may be necessary (see 5.3.4). It is preferable to start the heater outdoors for the first time, to allow any oils left over from the manufacturing process and transporting to be burnt off in a safe environment. Run it for 10 minutes on this first burn. 5.3.1. Carefully fill the fuel tank with clean approved fuel until fuel gauge (Fig.1B) points to ‘F’. 5.3.2. Ensure the fuel cap is secure. 5.3.3. Plug the power cord into a suitable power socket. If using an extension lead see Electrical Safety section 1.1. © Jack Sealey Limited IR37.V5 Issue 2 (H,2) 20/04/23 Original Language Version...
  • Page 4 Using a small amount of kerosene/paraffin/diesel, rinse and swirl the fuel around the fuel tank. Empty the tank completely. 6.6.3. Never store leftover kerosene/paraffin/diesel over the summer. Using old fuel can damage the heater. 6.6.4. Store heater in a dry, well ventilated area. 6.6.5. Be sure that the storage area is free of dust and corrosive vapours. Repack the heater in the original shipping material. Keep this User’s Manual in an easily accessible place. Fig.6 Fig.7 Fig.5 Fig.8 © Jack Sealey Limited IR37.V5 Issue 2 (H,2) 20/04/23 Original Language Version...
  • Page 5 Typically diesel can cloud in freezing conditions and will start to gel. You will need additives for your fuel in these conditions. Kerosene/Paraffin does not start to gel until the ambient temperature is around -40°C. © Jack Sealey Limited IR37.V5 Issue 2 (H,2) 20/04/23 Original Language Version...
  • Page 6 Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. If you require documentation for alternative versions, please email or call our technical team on technical@sealey.co.uk or 01284 757505. Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 sales@sealey.co.uk www.sealey.co.uk ©...
  • Page 7 The seasonal space heating Energy efficiency in active mode ƞ s,on The seasonal space heating energy efficiency ƞ ƞ 90.5 Energy efficiency classes Contact details: Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk, IP32 7AR. www.sealey.co.uk ERP Table 1...