Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear
Instruction
Protective gloves
Manual
(refuelling)
THIS HEATER IS NOT SUITABLE FOR USE AS A PRIMARY HEATING SOURCE
1. SAFETY
1.1.
ELECTRICAL SAFETY
WARNING! It is the user's responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and
all electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical
products.
If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable
Appliance Test) tested.
Electrical safety information, it is important that the following information is read and understood.
Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power
supply.
Regularly inspect power supply cables and plugs for wear or damage and check all connections to
ensure that they are secure.
Important: Ensure that the voltage rating on the appliance suits the power supply to be used and that
the plug is fitted with the correct fuse - see fuse rating in these instructions.
DO NOT pull or carry the appliance by the power cable.
8
DO NOT pull the plug from the socket by the cable.
8
DO NOT use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or
8
is replaced immediately by a qualified electrician.
This product is fitted with a BS1363/A 3 pin plug.
If the cable or plug is damaged during use, switch off the electricity supply and remove from use.
Ensure that repairs are carried out by a qualified electrician.
Replace a damaged plug with a BS1363/A 3 pin plug. If in doubt contact a qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualified electrician.
1.1.1.
If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance
plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that the
capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use
of 2.5mm² section cable.
1.2.
GENERAL SAFETY
▲
DANGER! Risk of carbon monoxide poisoning. Failure to provide proper ventilation could result in serious illness or death.
Check that the heater is in sound condition and good working order. Take immediate action to repair or replace damaged parts.
9
Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
9
Only use clean paraffin, diesel (NOT BIO-DIESEL) or kerosene to fuel this heater, in accordance with instructions contained in this
9
manual.
Locate heater on a level and stable surface.
9
Switch off if any irregularities occur.
9
WARNING! Only use heater in well ventilated areas. Ensure continuous ventilation is provided to the heater operating area via
windows and doors etc. If people are not required to be present in the heated area, the volume of air to be heated (mtr³)/
heat output (kW) ratio must be at least 10:1 and people must be advised not to remain in the heated area for prolonged periods. If
people are required to be present in the heated area, the volume of air to be heated (mtr³)/heat output (kW) ratio must be
at least 30:1. Ventilation must be to the outside of the premises in which the heater is to be operated. The total open area
(mtr²) must be at least 0.003 times the total heat output (kW). The volume concentration of oxygen (O²) in the heated room,
must always remain above 17%.
WARNING! DO NOT use the heater near flammable material, liquids, solids, gases or compressed gas cylinders etc.
DO NOT switch the heater off by disconnecting it from the mains. ALWAYS set the switch on the burner to the 'OFF' position and
8
allow the cooling cycle to finish, before disconnecting from the mains.
© Jack Sealey Limited
125,000BTU/HR INFRARED SPACE WARMER®
PARAFFIN/KEROSENE/DIESEL HEATER WITH
WHEELS
IR37.V5
MODEL NO:
Warning!:
DO NOT use
Hot surface
petrol
Original Language Version
Always unplug
Use heater in well
heater before
ventilated areas
servicing and
checking
Never use heater
where highly
flammable vapours
are present
RECOMMENDED
FUSE RATING: 3A
IR37.V5 Issue 2 (H,2) 20/04/23