Replacing the Oven Burner Nozzle
Open the appliance door.
1.
Remove the screws on the bake chamber cover and
2.
lift the front of the bake chamber cover slightly and
then pull it out towards you.
Remove the screws on the bake burner assembly and
3.
pull the burner forwards out of the gas connection.
Unscrew the bake burner nozzle and replace it with the
4.
LP nozzle number 120.
Reinsert the bake burner and screw tight.
5.
Reinsert the bake chamber cover and screw tight.
6.
Fill out the LP conversion label (included) and affix it to
7.
the appliance.