To install the iSCSI option ROM:
1.
Locate the BootIMG.FLB and Bootutil.exe files in the iSCSI folder on your SDVD.
2.
Copy the BootIMG.FLB and Bootutil.exe files to a bootable USB storage device.
3.
Enter DOS environment.
The utility must run under pure DOS environment. It cannot run in a DOS box on Windows
system. You should boot from a DOS floppy without any device drivers.
4.
Within the DOS environment, enter the directory with the BootIMG.FLB and Bootutil.
exe files.
5.
Install the iSCSI option ROM:
bootutil -nic=1 -up=iscsi -quiet
All ports share the same flash.
6.
Restart the system.
C:\I350>bootutil -nic=1 -up=iscsi -quiet
Intel(R) Ethernet Flash Firmware Utility
BootUtil version 1.5.94.2
Copyright(C) 2003-2015 Intel Corporation
Programming flash on port 1 with flash firmware image
/
Flash update successful
Port Network Address Location Series
==== =============== ======== ======= === ============================= =======
1
001FC6FFFFF1
2
001FC6FFFFF2
3
001FC6FFFFF3
4
001FC6FFFFF4
5
000C6E000072
C:\I350>