Download Print this page

Operation Instruction - Mitsubishi Electric RMF-CA200-V2 Installation Instructions Manual

Advertisement

5.0 Operation Instruction

Operate the third-party thermostat per the manufacturer's instructions. Simultaneous connection and use of RMF-CA200-V2 and Mitsubishi
remote controllers (e.g. MA/ME) is not supported as they will interfere with the correct RMF-CA200-V2 operation. Infrared Wireless remote
controller operation is NOT recommended after RMF-CA200-V2 installation. RMF-CA200-V2 and thermostat signals take precedence over
Mitsubishi wireless remote controller signals.
Notes:
The indoor unit will limit the internal temperature control set point based on the indoor unit specification.
Only fan speeds available on the Mitsubishi Electric indoor unit can be used by the Thermostat Interface.
Immediately
after cooling thermal OFF and 2 hours after heating thermal OFF, energizing G will place the IDU into fan mode.
Auto mode function is supported on multi-zone (MXZ) systems; however, cooling mode will not be available for 2 hours since the last heat call.
SW1-9 DIP switch is dedicated for toggling ON/OFF Fan mode to allow other unit(s) in heat stand by to operate. Only applicable to MXZ ported
systems.
5
© Mitsubishi Electric Sales Canada Inc. All rights reserved.
IM-RMF-CA200-V2-202306FM

Advertisement

loading