To Verify That All Stacks And Registers Are Restored Correctly Before Exiting A Subroutine - HP 16501A User Manual

Logic analysis system
Hide thumbs Also See for 16501A:
Table of Contents

Advertisement

Triggering
To verify that all stacks and registers are restored correctly before exiting a
subroutine
To verify that all stacks and registers are restored
correctly before exiting a subroutine
The exit code for a function will often contain instructions for deallocating
stack storage for local variables and restoring registers that were saved
during the function call. Some language implementations vary on these
points, with the calling function doing some of this work, so you may need to
adapt the procedure to suit your system.
Select the state analyzer Trigger menu.
1
Define terms SR_START and SR_END to represent the start and end
2
addresses of the subroutine.
Under State Sequence Levels, enter the following sequence
3
specification:
While storing "anystate" Find "SR_START" 1 time
While storing "anystate" Then find "SR_END" 1 time
While storing "anystate" TRIGGER on "≠ SR_START" 1 time Else on
"SR_START" go to level 2
Store "anystate"
Verifying Correct Return from a Function Call