Continuous Drainage

Continuous Drainage
Cautions when using the unit with continuous drainage
This dehumidifier is for home use. If you use it with continuous drainage, make sure to have a thorough check
for the following at least once every two weeks: dirty front filter, clogging of water hose, and resumption of
operation after a power failure. This will help to ensure trouble-free operation.
When a drain hose is to be used, make sure that the temperature around the hose does not fall below 0°C.
Water in the one might freeze causing undrained water to spill and wet household furniture or appliances.
To run the dehumidifier continuously it is necessary to have a suitable drainage point for accu-
mulated water.
Make sure to turn the unit off and then unplug it. Then proceed as follows.
1
Open a drain hose hole.
Remove the water tank. Using a screwdriver, punch a hole at the
drain hose hole located at the back of the unit. Smoothen the
edge of the hole with a hammer etc.
Insert the elbow joint into a hose (available
2
at hardware shop),
and insert the hose
through the drain
hose hole.
Remove the water tank. Insert
the hose through the drain hose
hole.
Insert elbow joint into the unit.
3
Insert the elbow joint into the drainage outlet of the unit all the way to the
joint base.
Re-install the water tank.
4
The unit does not operate without the water tank in place.
(The unit is turned off with water-brimmed direction device in the unit.)
Positioning of the
drainage hose for
continuous dehu-
midification
To stop continuous drainage and return
the dehumidifier to its original state
Move
Move
1
Drain water from
the tank.
2
Lift the carrying
handle.
(
Do not take out the water tank immediately after operation has stopped to prevent water leakage.
Cautions
Move the unit by lifting it up when the floor is easily damaged or at a rugged place. Do not use
the caster on a thick-piled carpet. This can cause damage to the surface of the carpet.
Commercial hose, 15mm diameter.
Elbow
joint
The hose
must be
below the
level of the
drainage
hole.
(by using caster)
Incline the unit.
3
7)
Insert more
than 10mm
into hose.
Do not bend
the hose.
At least 10cm
Pull the hose towards you. Then remove the hose from
the continuous drainage outlet (The drainage outlet should
be sealed with sticky tape, or other suitable means.)
Incline the unit
at an angle of
20 to 30 de-
grees by putting
your foot on the
back of the unit.
Rear view
Drain hose
Drainage outlet
Front view
The end of the
hose should
not come in di-
rect contact
with water.
Move
4
Over-inclination
might cause dam-
age to the floor
and water to leak.
Do not place
power supply
cord between
the caster.
Elbow
joint
17