Setup and function

Pos : 21 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Aufbau und Funkti on/T emperaturregler /Ver wendung 1094....1097, 1098 @ 26\mod_1342766379475_15.doc x @ 224403 @ @ 1
The temperature controller is used to control the temperature in closed rooms.
Pos : 22 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Übersc hriften (--> Für all e D okumente <--)/2. Ebene/A - F /Funkti ons- und Aus stattungs mer kmal e @ 23\mod_1336557630140_15.doc x @ 209136 @ 2 @ 1
6.1

Features of function and equipment

Pos : 23 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Aufbau und Funkti on/T emperaturregler /Funkti onen 1094....1097 @ 26\mod_1342708498968_15.doc x @ 224389 @ @ 1
Article no.
Features / Function
1094 ...
• Opens when the set temperature is reached.
• With separate connection for time-controlled reduction of nighttime temperature (4K).
• Servo valves of "closed when de-energized" design are required for the controller.
1095 ...
• Opens when the set temperature is reached.
• With normally open contact (not applicable for 1095 UF)
• With separate connection for time-controlled reduction of nighttime temperature (4K).
• With installed sliding switch and control lamp for nighttime temperature reduction (4 K).
• Servo valves of "closed when de-energized" design are required for the controller.
... UF
• With normally closed contact
• With remote sensor (external temperature sensor for mounting in the floor) and thermal feedback.
• For electric underfloor heating
• Opening of the relay contact, when the set temperature is reached.
1096 ...
• Opens when the set temperature is reached.
• With separate connection for time-controlled reduction of nighttime temperature (4K).
• With installed sliding switch and control lamp for nighttime temperature reduction (4 K).
• Servo valves of "closed when de-energized" design are required for the controller.
1097 ...
• With switchover contact (heating / cooling)
• Servo valves of "closed when de-energized" design are required for the controller.
... UTA
• With display of actual temperature
- Temperature display in steps of 0.5°C
• Display accuracy: ±0,5°C for load currents of ≤2 A
– Display accuracy: ±1,5°C for load currents of >2 A
• Automatic controller calibration
Pos : 24 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Steuer modul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1
Operating Instructions | 1473-1-8290
Setup and function
— 6 —