Siemens SIMATIC HMI IFP Operating Instructions Manual
Siemens SIMATIC HMI IFP Operating Instructions Manual

Siemens SIMATIC HMI IFP Operating Instructions Manual

Industrial flat panels
Table of Contents

Advertisement

Quick Links

IFP, IFP PRO, IFP ETH
SIMATIC HMI
Industrial Flat Panels
IFP, IFP PRO, IFP ETH
Operating Instructions
09/2019
A5E31298376-AJ
Preface
Overview
Safety information
Installing and connecting the
device
Commissioning the device
Operating the device
Maintaining and servicing
your device
Technical information
Technical Support
Markings and symbols
List of abbreviations
1
2
3
4
5
6
7
A
B
C

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC HMI IFP

  • Page 1 IFP, IFP PRO, IFP ETH Preface Overview SIMATIC HMI Safety information Installing and connecting the device Industrial Flat Panels IFP, IFP PRO, IFP ETH Commissioning the device Operating the device Operating Instructions Maintaining and servicing your device Technical information Technical Support Markings and symbols List of abbreviations 09/2019...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    Preface These operating instructions contain all the information you need for commissioning and operation of the SIMATIC Industrial Flat Panel IFP. It is intended both for programming and testing personnel who commission the device and connect it with other units (automation systems, programming devices), as well as for service and maintenance personnel who install add-ons or carry out fault/error analyses.
  • Page 4 Preface The devices IFP1900 PRO and PRO IFP2200 are referred to as "PRO devices". At some places in these operating instructions, the general term "Windows Embedded Standard" is used to refer to "Windows Embedded Standard 2009" and "Windows Embedded Standard 7". "Windows 7" is used as an abbreviation for "Windows 7 Ultimate". Figures This manual contains figures of the described devices.
  • Page 5: Table Of Contents

    Table of contents Preface ............................3 Overview ............................9 Product description ......................9 Scope of delivery ....................... 12 Design of the built-in units ....................13 1.3.1 IFP1500/1900/2200 Multitouch, IFP1900/2200 ETH ............13 1.3.2 IFP1500/1900/2200 Touch ....................15 1.3.3 IFP1500 Touch/Key ......................16 1.3.4 Interfaces ..........................
  • Page 6 Table of contents Mounting the PRO device ....................49 3.3.1 Notes on mounting ......................49 3.3.2 PRO devices for support arm (not extendable, flange top) and for pedestal (extendable, flange bottom) ....................51 3.3.3 PRO devices for support arm (extendable, round tube) ............53 Connecting the device ......................56 3.4.1 Notes on connection ......................56...
  • Page 7 Table of contents Technical information ........................87 Certificates and approvals ....................87 Directives and declarations ....................91 7.2.1 ESD guideline ........................91 Dimension drawings ......................94 7.3.1 Dimension drawing of the IFP1500 Multitouch ..............94 7.3.2 Dimension drawing of the IFP1500 Monitor and Touch ............95 7.3.3 Dimension drawing of the IFP1900 Multitouch and IFP1900 ETH ........
  • Page 8 Table of contents IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 9: Overview

    Overview Product description SIMATIC Industrial Flat Panels are LCD monitors suitable for industrial use with a brilliant TFT display which can be connected to all SIMATIC IPCs as well as almost all generally available PCs. IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 10 Overview 1.1 Product description Features of the built-in units ● Rugged front ● Brilliant TFT display with a wide reading angle; Resistive single touch screen in sizes 15", 19" and 22" Capacitive multi-touch screen available in sizes 15", 19" and 22" ●...
  • Page 11 Overview 1.1 Product description Additional features of the PRO devices ● All-round dust-proof and splash-proof with IP65 degree of protection and Enclosure Type 4X / 12 (indoor use only) ● Can be mounted directly on the machine ● 19" display, 22" display; capacitive multi-touch screen ●...
  • Page 12: Scope Of Delivery

    Overview 1.2 Scope of delivery Scope of delivery The product package includes the following components: Name Figure Number Industrial Flat Panel Installation instructions (Quick Install Guide) Accessory kit "Mounting clips power supply connector" "Connecting cables" accessory DVI connecting cable or DisplayPort connecting cable; 2 m in length, for commissioning USB connecting cable, 2 m in length Ethernet connecting cable, 2 m in length...
  • Page 13: Design Of The Built-In Units

    Overview 1.3 Design of the built-in units Design of the built-in units 1.3.1 IFP1500/1900/2200 Multitouch, IFP1900/2200 ETH This section describes the design of the multi-touch devices, using the IFP1900 Multitouch as an example. Front view and bottom view ① Display/touch screen ②...
  • Page 14 Overview 1.3 Design of the built-in units Rear view ① Rating plate ② Interface name ③ Equipotential bonding ④ Retaining elements for strain relief of the connecting cables IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 15: Ifp1500/1900/2200 Touch

    Overview 1.3 Design of the built-in units 1.3.2 IFP1500/1900/2200 Touch This section describes the design of the monitor and touch devices, using the IFP1500 Touch as an example. Front view and side view ① Display/touch screen ② Recesses for mounting clips ③...
  • Page 16: Ifp1500 Touch/Key

    Overview 1.3 Design of the built-in units 1.3.3 IFP1500 Touch/Key Front view ① Display and function keys with LED ② Alphanumeric keys ③ Control keys ④ Cursor keys ⑤ USB port 1.3.4 Interfaces 1.3.4.1 Standard versions ① X80 connector for 24 V DC power supply ②...
  • Page 17: Ethernet Monitor Devices

    Overview 1.3 Design of the built-in units 1.3.4.2 Ethernet Monitor devices ① X80 connector for 24 V DC power supply ② X1 Ethernet port ③ Reset button ④ X70 DisplayPort interface ⑤ X61/X62 USB Type A ⑥ X60 USB Type B 1.3.4.3 Extended versions ①...
  • Page 18: Design Of The Pro Devices

    Overview 1.4 Design of the PRO devices Design of the PRO devices 1.4.1 PRO devices for support arm (not extendable, flange top) The following figures show the design of the devices using the IFP1900 PRO for support arm (not extendable, flange top) as an example. Front view and side view ①...
  • Page 19: Pro Devices For Pedestal (Extendable, Flange Bottom)

    Overview 1.4 Design of the PRO devices Rear view ① Mechanical interface for fastening ② Rating plate ③ Enclosure ④ Backplane cover 1.4.2 PRO devices for pedestal (extendable, flange bottom) The following figures show the design of the devices using the IFP1900 PRO for pedestal (extendable, flange bottom) as an example.
  • Page 20 Overview 1.4 Design of the PRO devices Bottom view ① Mechanical interface for fastening Rear view ① Backplane cover ② Enclosure ③ Rating plate ④ Mechanical interface for fastening IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 21: Pro Devices For Support Arm (Extendable, Round Tube)

    Overview 1.4 Design of the PRO devices 1.4.3 PRO devices for support arm (extendable, round tube) The following figures show the design of the devices using IFP1900 PRO for support arm (extendable, round tube) as an example. Front view and side view ①...
  • Page 22: Interfaces

    Overview 1.4 Design of the PRO devices Rear view ① Mechanical interface for fastening (round tube) ② Terminal compartment cover ③ Nameplate ④ Mechanical interface below ⑤ Lower cover, included in the product package 1.4.4 Interfaces ① ⑤ Protective conductor terminal X61/X62 USB Type A ②...
  • Page 23: System Components And Accessories

    Overview 1.5 System components and accessories System components and accessories System components are products that have been developed for a specific system and can not be used in general, for example, like the base adapter. System components are always directly related to a core product. Accessories can typically be used for multiple devices from the same or different device families, for example, batteries, touch pens or protective membranes.
  • Page 24 ● Adapter set VESA100 for VESA100-compatible systems, Article number 6AV7674-0KD00-0AA0 In addition, other manufacturers offer support arm or pedestal systems with mechanical interfaces or adapters for Siemens PRO devices, e.g. RITTAL, ROLEC, BERNSTEIN, HASEKE, ROSE. Observe the specifications provided by the respective manufacturer. Flange mount adapter A flange mount adapter is available for mounting a PRO device for support arm (extendable, round tube).
  • Page 25 Overview 1.5 System components and accessories Extensions for PRO devices: The following example shows a PRO device for a support arm (extendable, round tube) with Extension Unit, Extension Unit box sowie en PRO Options handles and keyboard shelf with keyboard tray. ①...
  • Page 26 In addition, different operator controls, such as emergency stop button, selector switch, illuminated button, keyswitch and indicator light are available. Note Only operator controls with Siemens approval may be installed in the Extension Unit. Extension Unit box The Extension Unit box offers a deep empty housing to install larger customer-specific components underneat a 16:9 SIMATIC PRO device for pedestal (extendable, flange bottom) or for support arm (extendable, round tube).
  • Page 27: Accessories

    This section contains the number of accessories available at the time of publication of the operating instructions. You will find additional accessories on the Internet at: All Industrial Flat Panels ● Industry Mall (https://mall.industry.siemens.com) ● Expansion components and accessories (http://www.automation.siemens.com/mcms/pc- based-automation/en/industrial-pc/expansion_components_accessories) ●...
  • Page 28 Overview 1.5 System components and accessories Touch/Key Extended version Name Article number Film for labeling the function Print templates for the slide-in labels are 6AV7672-0DA00-0AA0 keys (slide-in labels) available on the "Documentation and Drivers" CD/DVD. Ethernet Monitors Name Specification Article number Recommended Ethernet RJ45 TP Cord RJ45/RJ45, 15 m 6XV1870-3QN15...
  • Page 29: Safety Information

    Safety information General safety instructions The device is designed for use in the industrial sector for operating and monitoring plant processes. Machinery Directive WARNING The device may only be used in machines which comply with the Machinery Directive The Machinery Directive specifies precautions to be taken when commissioning and operating machinery within the European Economic Area.
  • Page 30 In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks.
  • Page 31: Notes About Usage

    Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply latest updates may increase customer’s exposure to...
  • Page 32 Safety information 2.2 Notes about usage Industrial applications The HMI device is designed for industrial applications. It conforms to the following standards: ● Requirements for emissions EN 61000-6-4: 2007 ● Requirements for interference immunity EN 61000-6-2: 2005 Use in mixed-use zone Under certain circumstances you can use the HMI device in a mixed-use zone.
  • Page 33 (e.g. a clean air supply). • Only use suitable detergents. Observe the information regarding chemical resistance of the devices on the Internet (http://support.automation.siemens.com/WW/view/en/39718396). IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 34 Safety information 2.2 Notes about usage TFT displays NOTICE Burn-in effect, backlighting A permanent picture with bright screen objects can have a burn-in effect. An outline of the image is displayed for a while; the longer the image has been burnt-in, the longer the outline will be visible.
  • Page 35: Use In Hazardous Areas

    Safety information 2.3 Use in hazardous areas Use in hazardous areas The following warnings apply to operating a device with Ex approval in hazardous areas. WARNING Explosion Hazard Do not disconnect while circuit is live unless area is known to be non-hazardous. Substitution of components may impair suitability for Class I, Division 2 or Zone 2.
  • Page 36 Safety information 2.3 Use in hazardous areas IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 37: Installing And Connecting The Device

    Installing and connecting the device Preparing for installation 3.1.1 Checking the delivery package Procedure 1. When accepting a delivery, please check the packaging for visible transport damage. 2. If any transport damage is present at the time of delivery, lodge a complaint at the shipping company in charge.
  • Page 38: Built-In Unit

    Installing and connecting the device 3.1 Preparing for installation NOTICE Damage from condensation If the device is subjected to low temperatures or extreme fluctuations in temperature during transportation, as is the case in cold weather, for example, moisture can build up on or inside the device (condensation).
  • Page 39 Installing and connecting the device 3.1 Preparing for installation Mounting position Select one of the approved mounting positions for your device. The approved mounting positions are described in the following sections. Mounting in horizontal format All devices are suitable for horizontal mounting positions. A maximum ambient temperature of +50 °C is permitted for vertical mounting of the IFP1500 (0°...
  • Page 40: Checking Clearances

    Installing and connecting the device 3.1 Preparing for installation 3.1.2.2 Checking clearances The following clearances are required around the device to ensure adequate self-ventilation: ● At least 15 mm to the right and left of the mounting cutout (in x direction) to allow for insertion of the mounting clips during installation ●...
  • Page 41: Preparing The Mounting Cutout

    Installing and connecting the device 3.1 Preparing for installation 3.1.2.3 Preparing the mounting cutout Note Stability of the mounting cutout The material in the area of the mounting cutout must be sturdy enough to ensure permanent safe mounting of the device. To achieve the degrees of protection described below, it must be ensured that deformation of the material cannot occur due to the force of the mounting clips or operation of the device.
  • Page 42: Labeling The Function Keys

    Labeling strip templates are available in a Word document on the Internet at: Labeling strips for 15" widescreen (http://support.automation.siemens.com/DE/view/en/59000814) If you would like to make your own labeling strips, you can find the dimensions under "Dimensions for labeling strips (Page 108)".
  • Page 43 Installing and connecting the device 3.1 Preparing for installation The figure below shows the positions of the guides for the labeling strips of the 15" Touch/Key version. ① Guide for labeling strips F1, F3 ... F15 ② Guide for labeling strips F2, F4 ... F16 ③...
  • Page 44: Pro Devices

    Installing and connecting the device 3.2 Installing the built-in unit 3.1.3 PRO devices 3.1.3.1 Permitted mounting positions The device is intended for mounting on a support arm or stand. The figure below shows the permitted mounting positions and the associated ambient temperatures using a device for stand mounting as an example.
  • Page 45: Mounting Clips Or Mounting Brackets, Position For Ip65

    Installing and connecting the device 3.2 Installing the built-in unit ● Position the device so that it is not exposed to direct sunlight. ● Position the device so that it is easily accessible for the operator. ● Choose a suitable installation height. ●...
  • Page 46: Fastening The Device With Mounting Clips Or Mounting Brackets

    Installing and connecting the device 3.2 Installing the built-in unit Device Position Touch screen device with 22" display Touch/key device with: 15" display • 3.2.3 Fastening the device with mounting clips or mounting brackets Requirement ● All packaging components and protective films have been removed from the device. ●...
  • Page 47 Installing and connecting the device 3.2 Installing the built-in unit Proceed as follows: 1. Working from the front, insert the device into the mounting cut-out. Secure the device to prevent it from falling out. 2. Insert a mounting clip into the cutout provided on the device.
  • Page 48: Position Of The Mounting Clips For Ip66-Complaint Installation

    Installing and connecting the device 3.2 Installing the built-in unit 3.2.4 Position of the mounting clips for IP66-complaint installation Positions of the mounting clips To achieve IP66 degree of protection instead of IP65 for a device with capacitive multi-touch screen, fasten 4 additional mounting clips (available as accessories) at the positions marked by the red boxes.
  • Page 49: Mounting The Pro Device

    Installing and connecting the device 3.3 Mounting the PRO device Mounting the PRO device 3.3.1 Notes on mounting WARNING The device must be mounted securely. Inadequately dimensioned fasteners may cause the device to fall down. Serious physical injury may result. Make sure that fasteners are adequately dimensioned during installation.
  • Page 50 Liability disclaimer The device is mounted to a pedestal or a support arm via the mechanical interface with screws. Siemens AG assumes no liability for the consequences of incorrect installation. Warranty at risk If you do not install the HMI device in accordance with the specifications in these operating instructions, the warranty for the device is voided.
  • Page 51: Pro Devices For Support Arm (Not Extendable, Flange Top) And For Pedestal (Extendable, Flange Bottom)

    Requirement ● All packaging components and protective films have been removed. ● Siemens basic adapter with screws, included in product package of a PRO device for support arm (not extendable, flange top) or for pedestal (extendable, flange bottom). ● One of the following support arms or pedestal systems: –...
  • Page 52 A device for a support arm system cannot be used on a pedestal, and vice versa. 1. If an adapter plate for the Siemens base adapter is included in your support arm system, attach the adapter plate to the support arm with 4 M6x12 screws. Pay attention to the torque that is specified for the support arm.
  • Page 53: Pro Devices For Support Arm (Extendable, Round Tube)

    The following figures show an example of how to attach the PRO device to a support arm system using the optionally available Siemens flange mount. The same approach is used to mount the PRO device to a 48.3 mm round tube.
  • Page 54 3. Attach the flange mount or the 48.3 mm round tube with the two M8 threaded pins. Observe the appropriate torque: – Siemens flange mount: 8 Nm – 48.3 mm steel round tube 8 Nm – 48.3 mm aluminum round tube: 5 Nm...
  • Page 55 Installing and connecting the device 3.3 Mounting the PRO device 4. When you are using an adapter plate from a Siemens VESA adapter set, attach the adapter plate to the support arm with 4 M6x12 screws. When you are using another adapter plate matching the Siemens flange mount, attach the adapter plate to the support arm with the supplied mounting hardware.
  • Page 56: Connecting The Device

    Installing and connecting the device 3.4 Connecting the device Connecting the device 3.4.1 Notes on connection Requirement ● The device has been installed according to the information provided in these operating instructions. Connecting cables Note Use copper cables at connectors with terminal connections Use copper (Cu) cables for all supply lines that are connected to the device with terminals, e.g.
  • Page 57: Earthing The Device

    Installing and connecting the device 3.4 Connecting the device Connecting the cables NOTICE Observe local installation regulations Observe the local installation guidelines and the local installation conditions, such as protective wiring for power supply cables, when connecting the cables. Short-circuit and overload protection Different measures for short-circuit and overload protection are required when setting up an entire plant.
  • Page 58: Connecting The Power Supply

    Installing and connecting the device 3.4 Connecting the device Procedure The figure below shows the connection of a protective conductor in a built-in unit. Proceed the same way as you would when connecting an equipotential-bonding cable in a built-in unit or the PRO device.
  • Page 59: Connecting Devices With 24 V Dc 2-Pin

    An external protective circuit is required for operation with 24 V DC, see section 7 "Lightning protection and overvoltage protection" in function manual "Designing interference-free controllers (https://support.industry.siemens.com/cs/ww/en/view/59193566)". The following lightning protection element was used during the testing of the Industrial Flat Panel: Dehn BVT AVD 24" (Order No. 918 422)
  • Page 60 Installing and connecting the device 3.4 Connecting the device Procedure 1. Ensure that the cable ends of the power supply lines are fitted with end sleeves. 2. Switch off the 24 V DC power supply. 3. Fasten the end of a connecting cable L+ and a connecting cable M with the supplied power supply connector.
  • Page 61: Connecting Devices With 3-Pin 24 V Dc

    An external protective circuit is required for operation with 24 V DC, see section 7 "Lightning protection and overvoltage protection" in function manual "Designing interference-free controllers (https://support.industry.siemens.com/cs/ww/en/view/59193566)". The following lightning protection element was used during the testing of the Industrial Flat Panel: Dehn BVT AVD 24" (Order No. 918 422)
  • Page 62: Connecting An Ac Power Supply

    Installing and connecting the device 3.4 Connecting the device Procedure 1. Switch off the external 24 V DC power supply. 2. Connect the 24 V DC power supply connector to the device. Observe the correct polarity of the contacts: ① DC 24 V ②...
  • Page 63 Installing and connecting the device 3.4 Connecting the device Regional information Outside the United States and Canada, in regions with 230 V supply voltage: If you do not use the safety-certified power cable, use a flexible, double-insulated power supply cable (no single cables) with the following characteristics: ●...
  • Page 64: Connecting Ifp Standard, Extended And Pro To A Pc

    Installing and connecting the device 3.4 Connecting the device Procedure • Plug the connector of the supplied power supply cable into the AC power supply connector of the device. 3.4.4 Connecting IFP Standard, Extended and PRO to a PC 3.4.4.1 Overview Connection diagram for standard monitor version Connection diagram for standard touch version...
  • Page 65 Connection diagram for Extended versions and PRO devices (24 V DC only) Distance up to 5 meters Distance of 5m to 30m See also Internet entry for possible number of IFPs on different IPCs (https://support.industry.siemens.com/cs/ww/en/view/109483774) IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 66: Standard Version

    Installing and connecting the device 3.4 Connecting the device 3.4.4.2 Standard version Procedure 1. Connect the Flat Panel and the PC using a DVI or DisplayPort line. 2. If using a Touch version, also connect the device and the PC with a USB line.
  • Page 67: Connecting Ethernet Monitor To A Pc

    Connecting Ethernet Monitor to a PC 3.4.5.1 Overview Connection diagram for "Commissioning" mode Connection diagram for "Ethernet" mode See also Internet entry for possible number of IFPs on different IPCs (https://support.industry.siemens.com/cs/ww/en/view/109483774) IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 68: Connection Versions

    Installing and connecting the device 3.4 Connecting the device 3.4.5.2 Connection versions "Commissioning" mode When you commission an Ethernet Monitor with the "Ethernet Monitor" software or want to change the network parameters of an Ethernet Monitor, connect the Ethernet Monitor and IPC in the "Commissioning"...
  • Page 69: Securing The Cables

    Installing and connecting the device 3.4 Connecting the device Note Functional problem with USB port If you connect an external device with a 230 V power supply to the USB port without using a non-insulated installation, you may experience functional problems. Use a non-insulated system design.
  • Page 70: Securing Cables For Use In Hazardous Areas

    Installing and connecting the device 3.4 Connecting the device The figure below shows the fasteners of the IFP1900 PRO. 3.4.8 Securing cables for use in hazardous areas For securing the connected cables, use the appropriate mounting elements, as described in the previous chapter.
  • Page 71: Removing The Device

    Installing and connecting the device 3.5 Removing the device Removing the device 3.5.1 Removing the built-in unit The HMI deices is generally removed by following the steps taken to install in it but in the reverse order. Procedure Proceed as follows: 1.
  • Page 72: Removing A Pro Device

    Installing and connecting the device 3.5 Removing the device 3.5.2 Removing a PRO device The HMI deices is generally removed by following the steps taken to install in it but in the reverse order. Procedure Proceed as follows: 1. Close all open programs on the PC which is connected to the Flat Panel. 2.
  • Page 73: Commissioning The Device

    Commissioning the device If you operate the device exclusively as monitor and do not change the brightness, you do not need to commission the device. To use advanced functions of the device, perform the following commissioning. Requirement ● The Industrial Flat Panel is mounted according to the Quick Install Guide. ●...
  • Page 74 Commissioning the device IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 75: Operating The Device

    Operating the device Operator input options Depending on your device and the connected I/O devices, the following operator input options are available: ● Integrated keyboard on touch device (not for all IPC) ● Touch screen for touch device CAUTION Unintentional actions with touch screen operation If you touch the touch screen while system-internal processes are running, unintended reactions of the device may be triggered.
  • Page 76: Operating A Device With Resistive Single Touch Screen

    Operating the device 5.2 Operating a device with resistive single touch screen Operating a device with resistive single touch screen When you touch an object on the single touch screen, the corresponding function is performed. WARNING Personal injury or property damage due to incorrect operation Incorrect operation of devices with a touch screen can occur.
  • Page 77: Operating A Device With Capacitive Multi-Touch Screen

    Operating the device 5.3 Operating a device with capacitive multi-touch screen Operating a device with capacitive multi-touch screen You operate the multi-touch screen with one or multiple fingers. You can also operate it using gestures with up to five fingers at a time. WARNING Personal injury or property damage due to no earth connection An inadequate earth connection or the lack of one may cause malfunction of the capacitive...
  • Page 78 Operating the device 5.3 Operating a device with capacitive multi-touch screen WARNING Danger of malfunction due to improper execution of gestures on the touch screen If gestures are executed incorrectly on the touch screen with multi-touch function, these gestures may not be recognized or could be recognized incorrectly. The entries made are then not implemented by the device or are implemented incorrectly or in an unintended manner.
  • Page 79: Operating A Touch/Key Device

    Operating the device 5.4 Operating a Touch/Key device Functions of the multi-touch screen General functions ● Detection of up to 5 finger touches at a time. ● Detection of gestures that are supported by the operating system or the software installed on the device.
  • Page 80 Operating the device 5.4 Operating a Touch/Key device External keyboard Note The keyboard layout has been set to "English/USA international". If you use a keyboard with a layout other than the "English/USA international" layout, the key codes of the internal and external keyboards might no longer correspond.
  • Page 81 Operating the device 5.4 Operating a Touch/Key device Control keys The following table describes the control keys and their associated functions. With keyboard shortcuts, hold the first key down. Then press the second button. Key or keyboard shortcut Function Switch between upper and lower case: LED on: Upper case •...
  • Page 82: Advanced Device Functions

    Operating the device 5.5 Advanced device functions Cursor keys Key or keyboard shortcut Function Moves the cursor, selection or a controller in the specified direction. Moves the cursor or selection one page up. Moves the cursor or selection one page down. Moves the cursor to the start of the first screen.
  • Page 83: Maintaining And Servicing Your Device

    Maintaining and servicing your device General information on maintenance and servicing Observe the following when servicing and repairing protective equipment e.g. such as ground circuits or overvoltage protection components: ● Observe the maintenance and replacement intervals. ● Replace system components, including external cables, fuses and batteries only with equivalent components approved by the respective manufacturer.
  • Page 84: Ethernet Monitors - Diagnostics And Reset

    Maintaining and servicing your device 6.3 Ethernet Monitors - Diagnostics and reset Procedure 1. Switch off the device. This prevents the accidental triggering of functions when the screen is touched. 2. Dampen the cleaning cloth. 3. Spray the cleaning agent on the cloth and not directly on the device. 4.
  • Page 85: Restoring The Factory Settings For An Ethernet Monitor

    Maintaining and servicing your device 6.3 Ethernet Monitors - Diagnostics and reset 6.3.2 Restoring the factory settings for an Ethernet Monitor When the Ethernet Monitor was operated in the LAN network, it has an individual IP address. When you connect the Ethernet Monitor to another location in the network, it is no longer found because the Ethernet Monitor software is looking for the default IP address.
  • Page 86: Spare Parts And Repairs

    Kraftwerkstraße 25a 91056 Erlangen Germany See also Spare parts and repairs (http://support.automation.siemens.com/WW/view/en/16611927) Recycling and disposal Due to the low levels of pollutants in the HMI devices described in these operating instructions, they can be recycled. Contact a certified disposal service company for electronic scrap for environmentally sound recycling and disposal of your old devices, and dispose of the device according to the relevant regulations in your country.
  • Page 87: Technical Information

    P.O. Box 1963 D-92209 Amberg, Germany You can download information on the EC Declaration of Conformity, here under the keyword "Declaration of Conformity": ● IFP certificates (https://support.industry.siemens.com/cs/ww/en/ps/16788/cert) ● IFP PRO certificates (https://support.industry.siemens.com/cs/ww/en/ps/21662/cert) IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 88 Technical information 7.1 Certificates and approvals Software license agreements If the device is supplied with preinstalled software, you must observe the corresponding license agreements. UL approval Underwriters Laboratories Inc., to ● UL 508 (Industrial Control Equipment) ● CSA C22.2 No. 142 (Process Control Equipment) Underwriters Laboratories Inc., to ●...
  • Page 89 II 3 D Ex tc IIIC T 70 °C Dc Observe all information on the Internet (https://support.industry.siemens.com/cs/ww/en/view/291285) regarding use of the device in hazardous areas. When using the device in hazardous areas, ensure that all connectors connected to the device are secured in a captive manner, see section "Securing cables for use in hazardous areas (Page 70)".
  • Page 90 Technical information 7.1 Certificates and approvals FCC and Canada Federal This equipment has been tested and found to comply with the limits for a Class Communications A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed Commission to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 91: Directives And Declarations

    Technical information 7.2 Directives and declarations WEEE label (European Union) Disposal instructions, observe the local regulations and the section "Recycling and disposal (Page 86)". Marine approvals Acceptance procedures for shipping and offshore applications: ● ABS American Bureau of Shipping (USA) ●...
  • Page 92 Technical information 7.2 Directives and declarations NOTICE Damage to ESD from touch Electrostatic sensitive devices, ESD, can be destroyed by voltages which are far below the human perception limit. If you touch a component or electrical connections of a module without discharging any electrostatic energy, these voltages may arise.
  • Page 93 Technical information 7.2 Directives and declarations NOTICE Grounding measures There is no equipotential bonding without grounding. An electrostatic charge is not discharged and may damage the ESD. Protect yourself against discharge of static electricity. When working with electrostatic sensitive devices, make sure that the person and the workplace are properly grounded. Protective measures against discharge of static electricity ●...
  • Page 94: Dimension Drawings

    Technical information 7.3 Dimension drawings Dimension drawings 7.3.1 Dimension drawing of the IFP1500 Multitouch IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 95: Dimension Drawing Of The Ifp1500 Monitor And Touch

    Technical information 7.3 Dimension drawings 7.3.2 Dimension drawing of the IFP1500 Monitor and Touch IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 96: Dimension Drawing Of The Ifp1900 Multitouch And Ifp1900 Eth

    Technical information 7.3 Dimension drawings 7.3.3 Dimension drawing of the IFP1900 Multitouch and IFP1900 ETH IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 97: Dimension Drawing Of The Ifp1900 Monitor And Touch

    Technical information 7.3 Dimension drawings 7.3.4 Dimension drawing of the IFP1900 Monitor and Touch IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 98: Dimension Drawing Of The Ifp2200 Multitouch And Ifp2200 Eth

    Technical information 7.3 Dimension drawings 7.3.5 Dimension drawing of the IFP2200 Multitouch and IFP2200 ETH IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 99: Dimension Drawing Of The Ifp2200 Monitor And Touch

    Technical information 7.3 Dimension drawings 7.3.6 Dimension drawing of the IFP2200 Monitor and Touch IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 100: Dimension Dimensional Drawing Of The Ifp1900 Pro

    Technical information 7.3 Dimension drawings 7.3.7 Dimension dimensional drawing of the IFP1900 PRO IFP1900 PRO for pedestal (extendable, flange bottom) ① Without base adapter ② With base adapter IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 101 Technical information 7.3 Dimension drawings IFP1900 PRO for support arm (not extendable, flange top) ① Without base adapter ② With base adapter IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 102 Technical information 7.3 Dimension drawings IFP1900 PRO for support arm (extendable, round tube) ① With flange mount adapter ② Without flange mount IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 103: Dimension Drawing Of The Ifp2200 Pro

    Technical information 7.3 Dimension drawings 7.3.8 Dimension drawing of the IFP2200 PRO IFP2200 PRO for pedestal (extendable, flange bottom) ① Without base adapter ② With base adapter IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 104 Technical information 7.3 Dimension drawings IFP2200 PRO for support arm (not extendable, flange top) ① Without base adapter ② With base adapter IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 105 Technical information 7.3 Dimension drawings IFP2200 PRO for support arm (extendable, round tube) ① With flange mount adapter ② Without flange mount IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 106: Dimension Drawing Of The Ifp1500 Touch/Key

    Technical information 7.3 Dimension drawings 7.3.9 Dimension drawing of the IFP1500 Touch/Key IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 107: Dimension Drawing Host Unit Usb

    Technical information 7.3 Dimension drawings 7.3.10 Dimension drawing Host Unit USB The Host Unit USB is available as an accessory (DVI/USB cable sets >5 m). IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 108: Dimensions For Labeling Strips

    This section contains the dimensions of the labeling strips for 15" widescreen devices. Labeling strip templates are available in a Word document on the Internet at: Labeling strips for 15" widescreen (http://support.automation.siemens.com/DE/view/en/59000814) IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 109: Rating Plate

    Technical information 7.4 Rating plate Rating plate The rating plate includes information that clearly identifies your device. You need this information when you contact Customer Support. The figure below shows an example of a rating plate. ① Article number ② Serial number ③...
  • Page 110 Technical information 7.5 Technical specifications Display IFP1500 IFP1500 IFP1900 IFP2200 Type LCD widescreen TFT Active display area 15.4'' 15.6'' 18.5'' 21.5'' 344.2 × 193.5 mm 331.2 × 207 mm 409.8 × 230.4 mm 475.2 × 267.3 mm Resolution 1280 x 800 pixels 1366 x 768 pixels 1366 x 768 pixels 1920 x 1080 pixels...
  • Page 111 Technical information 7.5 Technical specifications Interfaces Monitor standard Touch standard Touch Extended/ IFP1500 versions versions PRO devices versions Touch/Key DVI-D DisplayPort USB Type A, rear USB Type A, front USB Type B, host USB-Link/Ethernet, RJ45 USB type A, maximum load 500 mA, equivalent to USB standard 2.0 DC power supply IFP1500 IFP1900...
  • Page 112: Ambient Conditions

    Technical information 7.5 Technical specifications 7.5.2 Ambient conditions 7.5.2.1 Transport and storage conditions Proper transport and storage, installation and assembly as well as careful operation and maintenance are prerequisites for trouble-free and safe operation of the device. Non-compliance with these regulations shall render the device warranty void. Mechanical transport and storage conditions The following information is for a device that is transported and stored in its original packaging.
  • Page 113: Operating Conditions

    Technical information 7.5 Technical specifications 7.5.2.2 Operating conditions Mechanical and climatic conditions of use The device is designed for use in locations protected from the effects of the weather. The conditions of use meet the requirements for DIN IEC 60721-3-3: ●...
  • Page 114 Technical information 7.5 Technical specifications Climatic ambient conditions The following table shows the climatic ambient conditions for operation of the device. Ambient conditions Permitted range Comments Temperature built-in units: 0 ... 50 °C (landscape format) Vertical mounting • 0 ... 40 °C (portrait format) 0 ...
  • Page 115: Electromagnetic Compatibility

    Powerful single pulse (surge) according to IEC 61000-4-5, external protective circuit is required (see function manual "SIMATIC S7-1500, ET 200MP, ET 200SP, ET 200AL Designing interference-free controllers", section 7 "Lightning protection and overvoltage protection") on the Internet (https://support.industry.siemens.com/cs/ww/en/view/59193566). Asymmetrical 2 kV power supply cable...
  • Page 116: Information On Insulation Tests, Protection Class And Degree Of Protection

    Technical information 7.5 Technical specifications Emission of radio interference The following table shows the emitted interference from electromagnetic fields according to EN 61000-6-4, measured at a distance of 10 m. Radiated emission (emitted interference) 30 MHz to 230 MHz < 40 dB (μV/m) quasi-peak 230 MHz to 1000 MHz <...
  • Page 117: Interface Description

    Technical information 7.6 Interface description Protection against foreign objects and water PRO device The device meets the requirements according to IEC 60529 and UL50. Degree of protection Explanation All-round When mounted: IP65 according to IEC 60529 • Enclosure Type 4X / 12 (indoor use only) according to UL50 •...
  • Page 118: Dvi-D Interface

    Technical information 7.6 Interface description 7.6.2 DVI-D interface DVI-D interface Pin no. Abbreviation Signal TX2N TDMS data 2- TX2P TDMS data 2+ TMDS data shield 2, ground Not assigned Not assigned DDC CLK DDC clock DDC CLK DDC data Not assigned TX1N TDMS data 1- TX1P...
  • Page 119: Displayport

    Technical information 7.6 Interface description 7.6.3 DisplayPort DisplayPort interface Pin no. Abbreviation Meaning Input/output ML_Lane3- DP data 3- Input Ground ML_Lane3+ DP data 3+ Input ML_Lane2- DP data 2- Input Ground ML_Lane2+ DP data 2+ Input ML_Lane1- DP data 1- Input Ground ML_Lane1+...
  • Page 120: Usb Hub, Type A

    Technical information 7.6 Interface description 7.6.5 USB hub, Type A USB port Pin No. Abbreviation Signal + 5 V (fused) - Data Data channel + Data Data channel Ground 7.6.6 Ethernet Ethernet RJ45 interface Pin no. Short description Meaning Input / output BI_DA+ Bi-directional data A+ Input/output...
  • Page 121: Technical Support

    You can find additional information and support for the products described on the Internet at the following addresses: ● Technical support (https://support.industry.siemens.com/cs/ww/en/) ● Support request form (http://www.siemens.com/automation/support-request) ● After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) ● SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) ● Your local representative (http://www.automation.siemens.com/mcms/aspa-db/en/Pages/default.aspx) ●...
  • Page 122: Troubleshooting

    Technical Support A.2 Troubleshooting Troubleshooting Ethernet Monitors Error pattern Possible cause Possible remedy The Windows Start screen is Occurs when Uninstalling cannot be performed with an not visible and only the uninstalling the Ethernet Monitor. Use a different monitor extended desktop is displayed. for uninstalling.
  • Page 123: Markings And Symbols

    Markings and symbols Safety-relevant symbols The following table describes symbols that can be added to your SIMATIC device, to its packaging or to an enclosed document in addition to the symbols described in the manuals. Symbol Meaning Reference General danger sign Caution / Attention ISO 7000 No.
  • Page 124 Markings and symbols B.1 Safety-relevant symbols Symbol Meaning Reference Only for industrial applications and indoor areas (control cabinet) Install in control cabinet only Devices approved for Ex Zone 2 in a control cabinet with min. IP54 Devices approved for Ex Zone 22 in a control cabinet with min. IP6x IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 125: List Of Abbreviations

    List of abbreviations ANSI American National Standards Institute ASCII American Standard Code for Information Interchange Width Backlight Inverter BIOS Basic Input Output System CD-ROM Compact Disc – Read Only Memory Central Processing Unit Direct Current DHCP Dynamic Host Configuration Protocol Domain Name Service Distributed I/O Data Source Name...
  • Page 126 List of abbreviations IFP, IFP PRO, IFP ETH Operating Instructions, 09/2019, A5E31298376-AJ...
  • Page 127: Glossary

    Glossary Application An application is a program which is put directly on the operating system MS-DOS or windows. An application on the PC/PG, for example, is STEP 7. Controller Installed hardware and software which control the functions of specific internal or external devices, e.g.
  • Page 128 Glossary Module Modules are plug-in units for PLCs, programming devices or PCs. Modules exist, for example, as central modules, power-ons, or as mass storage. Plug and play Through plug and play, the computer configures itself automatically to be able to communicate with peripheral devices, e.g.
  • Page 129: Index

    Index Connecting, 66 2-pole DC power supply, 59 3-pole DC power supply, 61 AC power supply, 62 Abbreviations, 125 Cables, 57 AC power supply DVI, 66 Technical specifications, 111 Protective conductor, 58 ACK key, 81 USB, 66 Acknowledge key, 81 USB device, 68 Alphanumeric keys, 80 Connecting the PE conductor, 58...
  • Page 130 Index ESD, 30, 91 ESD Directive, 91 Ethernet interface, 120 ACK, 81 Ethernet Monitor ALT, 81 Views, 13 Backspace, 81 Extension Unit, 25 Cancel, 81 Maximum number, 25 CTRL, 81 Extension Unit box, 26 Cursor, 82 Delete, 81 END, 82 ENTER, 81 Factory settings ESC, 81...
  • Page 131 Index Mounting position Protection class, 116 Built-in unit, 39 Protective conductor, 57 Protective measure PRO device, 44 Multi-touch device Static electricity, 93 Views, 13 Radiation, 29 New Zealand, 90 High-frequency radiation, 29 Note Radio interference, 32 General information, 33 Emission, 116 Rated load Interface, 69 Recycling, 86...
  • Page 132 Index TAB key, 81 Technical specifications, 109 Test For ambient conditions, 113 Touch screen Operation, 75 Touch screen device Views, 15 Touch/key device Views, 16 Transport and storage conditions, 112 Troubleshooting Ethernet Monitor, 122 Turning off, 58 UL approval, 88 USA, 63 USB device Connecting, 68...

This manual is also suitable for:

Simatic hmi ifp proSimatic hmi ifp eth

Table of Contents