Specification; Installation - Sealey SAC12000.V3 Quick Start Manual

Air conditioner/dehumidifier/heater

Advertisement

2.
INTRODUCTION
i
Thermostatically controlled unit with extendible exhaust hose and window kit - ideal for home or office environments. Features three-speed fan
and electronic remote control. Air conditioning temperature range 16-30°C. Also features heating and dehumidifying functions. Dehumidifier
capable of removing up to 28.8L/day. Refrigerant is R290 300g. Mounted on castors for manoeuvrability. Cable storage keeps unit tidy when not
in use.

3. SPECIFICATION

MODEL NO: ................................................... SAC12000.V3
Cooling Capacity: ................................................12000Btu/hr
Discharge Side Pressure: ..........................................2.8MPa
Energy Class:...................................A (Cooling) A+ (Heating)
IP rating ..........................................................................IP20
Mass of refrigerant: ........................................................ 300g
Max. airflow: .............................................................435m³/hr
Max. exhaust hose length: ............................................. 1.5m
Max. water extraction rate: ..................................... 28.8L/day
Noise level: .............................................................. 65db (A)
Power: ..............................1340W (Cooling) 1235W (Heating)
Rated capacity: ................3500W (Cooling) 3250W (Heating)
Refrigerant: ................................................................... R290
Suction side pressure: ...............................................0.8MPa
Supply: ................................................................ 230V~50Hz

4. INSTALLATION

IMPORTANT: Allow the refrigerant to settle for at least 24 hours before using the unit.
4.1.
EXHAUST HOSE ASSEMBLY
4.1.1.
Snap the two halves of the hose adaptor (fig.1.13) together (DO NOT use excessive force).
4.1.2.
Pull one end exhaust hose (fig1.14) out from its closed position.
4.1.3.
Insert the end into the exhaust air outlet (fig.1.8) and turn in an anticlockwise direction until tight.
4.1.4.
Pull the free end out and screw the assembled hose adaptor onto the outer end of the exhaust hose in an anticlockwise direction until
tight.
4.2.
WINDOW ADAPTOR
4.2.1.
Slide the window adaptor to the correct width for the window opening and locate the stop screw in the relevant screw hole to stop the
slide closing.
4.2.2.
Close the window onto the window adaptor, clamping it in place. This can be achieved with sash windows, sliding windows or vertically
hinged windows.
4.2.3.
Insert the hose adaptor into the window adaptor (figs 2 and 3).
DO NOT use an extension hose or hose different from the one supplied. The length
8
and diameter of the hose supplied are the optimum size for this unit. Changing those
dimensions could affect the performance.
4.3.
LOCATION
The SAC12000 should be located on a flat floor and be 500mm clear of any surrounding objects.
© Jack Sealey Limited
Get In Touch
Call: 0845 6880112
Email: info@adremit.co.uk
fig.2
Original Language Version
Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
fig.1
fig.3
SAC12000.V3 Issue 1 11/03/20