5-6. Reference
(1) Brightness : Full white 216 Gray
(2) Standard color coordinate and white balance when using
the CS-1000
Mode
Color Coordination
x
COOL
0.276
MEDIUM
0.285
WARM
0.313
(3) Standard color coordinate and white balance when using
the CA-210 (CH 10)
Mode
Color Coordination
x
COOL
0.276±0.002
MEDIUM
0.285±0.002
WARM
0.313+0.002
6. HDCP (High-Bandwidth Digital
Contents Protection) SETTING
- Set write size to 64 bytes
- Set delay time to 250ms
- Connect D-sub Signal Cable to D-Sub Jack
- Input HDCP key with HDCP-key- in-program
- HDCP Key value is stored on EEPROM(AT24C512) which is
80~A1 addresses of 0xA0~0xA2 page
- AC off/ on and on HDCP button of MSPG925 and confirm
whether picture is displayed or not of using MSPG925
- HDCP Key value is different among the sets.
7. Select the option by country
7-1. Overview
1) The option selection is applied to the North American
model only, which selects the rating related country.
2) Applied models: LA89D Chassis applied None USA
Model(Canada, Mexico)
7-2. How to select
1) Press the In-Start key of the R/C and press the red oval
OP1(PIP CH-) key to enter into the Factory Option menu.
2) Select 1.USA, 2.CANADA or 3.MEXICO from the country
select according to the destination. At this time, use the
volume +/- key to adjust
7-3. Set the shipping mode (In-stop)
- After completing the final test, in order to set the set to the
shipping condition, press the In-Stop key of the R/C to make
sure that the set is turned off.
Copyright © 2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Temp
y
0.283
11000K
0.293
9300K
0.324
6500K
Temp
y
0.283±0.002
11000K
0.293±0.002
9300K
0.324±0.002
6500K
8. GND and resisting pressure test
8-1. How to test
(1) Preparing for the automatic test on the GND & resisting
pressure
∆UV
- Make sure that the power cord is inserted into the set
completely. (When it is disconnected or loosened, test
after inserting it)
0.0000
(2) Perform the automatic test on the GND & resisting pressure
1) The set with power cord, the cord and the A/V
0.0000
completely inserted into the tuner is loaded on the pallet
0.0000
and entered into the automatic test process.
2) Connect the D-terminal AV JACK tester
3) Turn on the automatic (GWS103-4)
4) Perform the GND TEST
5) If it is not good, the buzzer is operated to notify the test
result to the operator.
∆UV
6) If it is OK, it is automatically switched to the resisting
pressure test. (Disconnect the cord and the A/V from the
0.0000
AV JACK BOX)
6) Perform the resisting pressure test
0.0000
7) If it is not good, the buzzer is operated to notify the test
0.0000
result to the operator.
8) If it is OK, the GOOD LAMP is turned and the stopper is
moves down, and it moves to the next process.
8-2. Items to manage
(1) TEST voltage
- GND : 1.5KV/min at 100mA
- SIGNAL : 3KV/min at 100mA
(2) TEST time:1 second
(3) TEST POINT
- GND test = between Power cord GND and Signal cable
metal GND
- Resisting pressure test = between Power cord GND and
Live & Neutral
(4) LEAKAGE CURRENT: Set to 0.5mArms
- 14 -