Rf382R - Siemens SIMATIC Ident RF340R02 System Manual

Table of Contents

Advertisement

Planning the RF300 system
4.3 Installation guidelines
4.3.4.5

RF382R

Note
RF382R not suitable for metallic surroundings
The RF382R was not developed for reading transponders in a metallic environment.
With ISO transponders (MDS D)
Table 4- 56
Transponder
MDS D124
MDS D160
MDS D324
MDS D424
MDS D460
Values of > 100 % can occur if transponders were developed specifically for mounting in/on metal-
1)
lic surroundings.
96
Reduction of field data by metal (in %): Transponder and RF382R
Without metal
Without metal
Without metal
Without metal
Without metal
Reader RF382R (ISO mode)
Without metal
100
100
100
100
100
System Manual, 07/2017, C79000-G8976-C345-07
On metal
110
1)
100
110
1)
105
1)
115
1)
SIMATIC RF300

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic ident rf300Simatic ident rf310r02

Table of Contents