Installation Instructions
3/8" DIAMETER
THREADED ROD
(6 PLACES)
HOLD DOWN NUTS
SUPPORT NUTS
2"X2"X1/8" ANGLE IRON
(3 PLACES)
Figure 10
Horizontal Installation
GAS LINE WITH DRIP
LEG (3" MINIMUM)
Figure 11
Horizontal Installation
1 6 |
POSITION AS CLOSE AS POSSIBLE
TO BLOWER DECK TO ALLOW FOR
CIRCULATOR BLOWER REMOVAL
DRAIN PAN
FURNACE MUST BE SUPPORTED
AT BOTH ENDS AND MIDDLE
PROVIDE 8" MINMUM CLEARANCE BETWEEN
CENTER ROD AND FURNACE CABINET
TO ALLOW FOR CIRCULATOR BLOWER REMOVAL
FURNACE MUST BE LEVEL
FROM END TO END.
FURNACE MUST BE SLIGHTLY TILTED
FORWARD WITH THE DOORS 1/2"~3/4"
BELOW THE BACK PANEL.
7" MINIMUM DRAIN
TRAP CLEARANCE
36" MINIMUM SERVICE
CLEARANCE REQUIRED
Bosch 96% AFUE Condensing Gas Furnace - BTC 770503101 J (06.2023)
ASSURE FURNACE IS LEVEL FROM
END TO END AND HAS A SLIGHT
FORWARD TILT WITH THE FRONT
OF THE FURNACE 3/4"
BELOW THE BACK OF THE FURNACE
TILT OUTWARD TO ALLOW FOR
DOOR AND CIRCULATOR BLOWER
REMOVAL
DRAIN LINE WITH 1/4" PER
FOOT DOWNWARD SLOPE