Chapter 9

9.3.2 Protection Function

9.3.2.1 Protective Functions

0013-1190
/ / / / iR1018 / iR1018J / / iR1022A / iR1022F / iR1022i / iR1022iF /
The power supply PCB is equipped with an over-current/over-voltage protection mechanism to prevent damage to the power circuit in the event of an over-current
or over-voltage, as caused by a short circuit or the like on the load side.
If the over-current/over-voltage protective mechanism has gone ON, disconnect the power cord, and correct the fault; then, connect the power cord once gain to
reset the machine. If short circuiting and resetting are repeated, the internal fuse (F1, F2) can melt.