If a gas leak is found or suspected, immediately turn off the gas cylinder, switch the heater off and DO NOT use again until it has
9
been checked by a qualified service centre. If the heater is installed indoors, provide good ventilation by opening doors and windows
completely. DO NOT produce sparks or open flames.
Ensure the fan is operating correctly before lighting the burners.
9
If the heater has to work for a long periods at its maximum capacity it is possible that ice will form on the cylinder. This is due to
9
excessive vapour withdrawal. NEVER heat the cylinder for this or any other reason. To avoid this effect or at least reduce it, use a
large cylinder or at least two cylinders linked together, see fig.1.
WARNING! Disconnect heater from mains electrical supply and gas cylinder before servicing or performing maintenance. Replace or
repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental
capabilities or lack of experience or knowledge if they have been given supervision or instruction concerning the use of the appliance
in a safe way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and maintenance shall not be undertaken by children without supervision.
9
Children of less than 3 years should be kept away unless continuously supervised.
9
2. INTRODUCTION
61,000-102,000Btu/hr (18-30KW) variable output Propane Space Warmer®. Features safety solenoid valve which prevents the unit from leaking
gas and safely ignites by the Piezo push-button ignition system. Supplied with a fully approved gas regulator and hose. The Space Warmer® is fan
assisted and as the fuel is completely burned it leaves no oily residue like you may experience when using other types of fuel heaters. There is no
odour, except for the few seconds during start-up and the unit runs a little more quietly since they do not need a compressor to drive the fuel to the
burner. Heats an area of 15,900ft³(450m³) with a fuel consumption of 1.3-2.18kg/hr.
3. SPECIFICATION
Model no: .............................................................. LP100.V7
Airflow: ....................................................................... 380cfm
Fuel Consumption: ............................................ 1.3-2.18kg/hr
Fuel: ..........................................................................Propane
Fuse Rating: ......................................................................5A
Heated Area: ................................................15,900ft³(450m³)
Output: ................................ 61,000-102,000Btu/hr(18-30kW)
Power Supply Cable Length: .......................................... 1.2m
Supply: ...........................................................................230V
4. OPERATION
4.1.
Refer to instructions in Safety section 1 above.
4.2.
Safety clearance see fig.2.
4.3.
Connect gas supply hose to pressure regulator and
connect regulator to a suitable LPG cylinder
(left hand threaded nut).
4.3.1.
Open the gas cylinder tap and check supply hose and
fittings for gas leaks. Use an approved leak detector or
soapy water.
WARNING! NEVER USE NAKED FLAMES
4.4.
Connect to mains power.
4.5.
IGNITION
4.5.1.
Turn the power switch to position "I" and check the fan
starts running correctly.
4.5.2.
Push the gas valve button and repeatedly push the
piezoelectric lighter until the flame lights up see fig.3.
CAUTION If ignition is difficult or irregular before
repeating the ignition operations make sure that
the fan is not locked and that the air inlet and outlet
are unobstructed.
4.6.
SWITCH OFF
4.6.1.
To stop the heater shut off the gas cylinder tap.
4.6.2.
Let the fan run until the flame shuts down and then turn
the fan switch to position "O".
4.7.
ASPHYXIATION HAZARD
DO NOT use in domestic situations.
8
DO NOT use in unventilated areas. The flow of combustion and ventilation air must not be obstructed. Proper ventilation air must be
8
provided to support the combustion.
WARNING! If gas is smelt immediately switch off appliance at the gas bottle. Check the appliance for leaks using an approved leak
detector, if the leak can not be found switch off gas supply and seek professional help. Be aware that in the event of a gas leak ensure
that the area is fully ventilated and any form of ignition should be avoided.
5. MAINTENANCE
5.1.
Repairs and maintenance must only be carried out by qualified personnel.
5.2.
The heater must be checked by a qualified technician at least once a year.
5.3.
Regularly check the condition of the gas hose and gas regulator. If it must be replaced only use genuine spare parts. Failure to do so may
result in personal injury and will invalidate the warranty.
5.4.
Check the starting electrode position, see fig.4.
© Jack Sealey Limited
fig.1
fig.2
fig.3
Original Language Version
LP100.V7
Issue 3 (H,2,3) 19/04/23