DRILL PILOT HOLES AND FASTEN BRACKET
Drill a
/
-inch pilot hole where screws are to be located. If bracket
1
8
is to be mounted to the wall, drill pilot hole at an approximate 20
degree downward angle. If bracket is to be mounted to masonry or
ceramic floors, drill a
/
-inch pilot hole 1
5
32
screws provided may be used in wood or concrete material. Use a
5
/
-inch nut-driver or flat head screwdriver to secure the bracket
16
in place.
FASTEN BRACKET
(WALL OR FLOOR MOUNTING)
leveling leg
floor mount
Figure 14
FASTEN BRACKET
(FLOOR MOUNTING ONLY)
leveling leg
floor mount
Figure 15
3
/
inches deep. The
4-
/
1
max 1
"
4
wall mount
wall plate
Anti-Tip bracket
more than
/
1
1
"
4
wall
Anti-Tip bracket
INSTALLATION MANUAL
3
LEVEL AND POSITION RANGE
Level range by adjusting the (4) leveling legs with a wrench.
Note: A minimum clearance of 1 /8-inch is required between the
bottom of the range and the leveling leg to allow room for the
bracket. Use a level to check your adjustments. Plug range into
properly prepared electrical receptacle or if hard wired, check that
it was completed properly. Check floor condition for evenness and
stability. Slide range back into position.
5
/
"
1
8
Range Slide
Figure 16
Visually check that rear leveling leg is inserted into and fully
secured by the Anti-Tip bracket by looking underneath the range
with a flashlight and carefully attempt to tilt it forward.
Slide range in cabinet until control panel edge
Figure 17
is flush with the countertop front edge.